tmp07103 Traco Power, tmp07103 Datasheet - Page 3

no-image

tmp07103

Manufacturer Part Number
tmp07103
Description
Ac/dc Power Modules
Manufacturer
Traco Power
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP07103
Manufacturer:
TRACOPOWER
Quantity:
652
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Input Specifications
Input current at full load (115 VAC / 230 VAC)
Input current at no load (115 VAC / 230 VAC)
Inrush current (< 2ms, cold start at 115 VAC / 230 VAC)
External input fuse required (recommended value)
Output Specifications
Voltage set accuracy
Regulation
Minimum load
Ripple and noise (20MHz bandwidth)
Overload protection by current limit
Overvoltage protection by Zehner diode (main output only)
Rise time
Hold-up time
Max. capacitive load [µF]
Single output
models:
Dual output
models:
Triple output
models:
Output:
3.3 VDC
5.0 / 5.1 VDC
12 / 15 VDC
24 VDC
36 VDC
48 VDC
5 VDC
+12 / –12 / +15 / –15 VDC
3.3 / 5.0 VDC
+12 / –12 / +15 / –15 VDC
– Input variation
– Load variation
dual output models unbalanced load (20/100%): 5.0% max.
triple output models auxiliary outputs (10–100%): 4.0% max.
dual output models balanced load (10–100%): 2.5% max.
triple output models main output (10–100%): 1.0% max.
triple output models auxiliary outputs: 20% of rated max. current
single output models (10–100%): 1% max.
triple output models main output: 10% of rated max. current
3.3 VDC & 5.0 VDC outputs: 1.8% of Vout [mVpk-pk]
single an dual output models: 10% of rated max. current
TMP 07
2200
2200
1000
6800
-
-
-
-
-
-
7 – 10 W modelss: 10 A / 20 A
7 - 30 W models: 1.5 A slow blow
30 W models: 550 mA / 330 mA typ.
60 W models: 1050 mA / 670 mA typ.
30 W models: 20 A / 40 A
60 W models: 30 A / 50 A
10 W models: 200 mA / 130 mA typ.
15 W models: 300 mA / 190 mA typ.
15 W models: 15 A / 30 A
7 W models: 150 mA / 100 mA typ.
other models: 3.0 A slow blow
other outputs: 1.3% of Vout [mVpk-pk]
TMP 10
3900
3300
2200
1000
1000
-
-
-
-
-
15 mA / 20 mA typ.
±2% max.
1% max.
operation at lower load condition will not
damage these power supplies, how ever, they
may not meet all listed specifications.
120% – 180% of Inom, fold back, automatic
recovery (long term overload condition may
cause damage to the power supply)
120% of Vout typ.
200 ms typ.
20 ms typ.
AC/DC Power Modules
TMP Series
Model series
TMP 15
3900
2200
1000
2000
1500
2200
1500
680
-
-
General Specifications
TMP 30
8000
3900
1500
1000
3900
1500
2200
1500
-
-
7 to 60 Watt
Page 3 of 11
TMP 60
8000
3900
1500
1000
800
-
-
-
-
-

Related parts for tmp07103