tmp17gs-reel Analog Devices, Inc., tmp17gs-reel Datasheet
tmp17gs-reel
Related parts for tmp17gs-reel
tmp17gs-reel Summary of contents
Page 1
... A/K 273 248 –45 –25 0 TEMPERATURE – C Figure 1. Transfer Characteristic One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781/329-4700 Fax: 781/326-8703 © 2003 Analog Devices, Inc. All rights reserved. * TMP17 ...
Page 2
... C (298 Over Rated Temperature Note 150 C for 500 Hrs V– +373 +423 +100 +150 Model +200 +300 TMP17FS 2.5 C +212 273.15 TMP17GS 3.5 C –2– ≤ 105 C, unless otherwise noted.) Min Typ Max ± 2.5 ± 3.5 ± 3.5 ± 4.5 0.5 0.3 0.3 2 0.5 298.2 1 0.2 4 0.2 4 ...
Page 3
–1 – –3 –4 –5 –6 –50 – TEMPERATURE – C TPC 1. Accuracy vs. Temperature 100 ...
Page 4
... Specifications table. The error limits are a combination of initial error, scale factor variation, and nonlinearity deviation from the ideal 1 µA/K output. TPC 1 graphically depicts the guaranteed limits of accuracy for a TMP17GS. The TMP17 has a highly linear output in comparison to older technology sensors (i.e., thermistors, RTDs, and thermocouples), thus a nonlinearity error specification is separated from the absolute accuracy given over temperature ...
Page 5
If greater accuracy is desired, initial calibration and scale factor errors can be removed by using the TMP17 in the circuit of Figure 5. 5k 97.6k + 8.66k REF43 OP196 7.87k + TMP17 – V– Figure 5. Two ...
Page 6
TMP17 The circuit in Figure 8 demonstrates a method in which a voltage output can be derived in a differential temperature measurement 10k TMP17 – OP196 R1 TMP17 50k – 10k –V Figure 8. Differential Measurements ...
Page 7
R and R determine the limits of temperature controlled HIGH LOW by the potentiometer R . The circuit shown operates over the SET temperature range – +105 C. The reference maintains a constant set point voltage and ensures ...
Page 8
TMP17 0.25 (0.0098) 0.10 (0.0040) COPLANARITY CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS (IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN Revision History Location 1/03—Data Sheet changed from REV ...