vre402 Rhopoint Components, vre402 Datasheet - Page 17
vre402
Manufacturer Part Number
vre402
Description
Precision Dual Reference
Manufacturer
Rhopoint Components
Datasheet
1.VRE402.pdf
(20 pages)
MODEL
PARAMETER
ABSOLUTE RATINGS
OUTPUT VOLTAGE
OUTPUT VOLTAGE ERRORS
OUTPUT CURRENT
REGULATION
POWER SUPPLY CURRENTS
+PS
-PS
ELECTRICAL SPECIFICATIONS
NOTES:
1. The specified values are without external trim.
2. The temperature coefficient (tc) is determined by the
3. The tracking error is the deviation between the
Vps = ± 15V, T = 25°C, RL = 10K
Power Supply
Operating Temp. (
Operating Temp. (
Storage Temperature
Short Circuit Protection
VRE410
Initial Error
Warmup Drift
T
Tracking Error
Long-Term Stability
Noise (.1-10Hz)
Range
Line
Load
box method using the following formula:
positive and negative output over the operating temp.
range.
min
tc =
- T
max
*Same as A/J Models.
(2)
(1)
V
nominal
V
(3)
max
A,B,C
J,K,L
- V
x (T
)
unless otherwise noted.
min
)
max
±13.5
±10
-40
-65
MIN
-T
0
(4)
min
Continuous
)
±10.00
x 10
A/J
TYP
±15
1
6
6
3
3
7
4
6
+150
1.00
±22
+70
+85
MAX
0.6
0.5
10
9
6
MIN
*
*
*
*
*
B/K
TYP
2
*
*
*
*
*
*
*
*
*
4. The specified values are unloaded.
1.60
MAX
1.0
0.7
*
*
*
*
*
*
*
MIN
*
*
*
*
*
C/L
TYP
3
*
*
*
*
*
*
*
*
*
2.00
MAX
2.0
1.0
*
*
*
*
*
*
*
VRE410DS REV. A MAY 1996
VRE410
ppm/1000hrs
ppm/mA
ppm/ C
ppm/V
UNITS
ppm
mV
mA
mA
mA
Vpp
°C
°C
°C
mV
V
V