acpl-772l Avago Technologies, acpl-772l Datasheet
acpl-772l
Available stocks
Related parts for acpl-772l
acpl-772l Summary of contents
Page 1
... Digital Fieldbus Isolation: DeviceNet, Profibus, SDS L • Multiplexed Data Transmission • General Instrument and Data Acquisition • Computer Peripheral interface • Microprocessor System Interface for 1 min. per UL1577 for ACPL-772L rms for 1 min. per UL1577 for ACPL-072L rms = 630 V for ACPL-772L Option 060 ...
Page 2
... To order, choose a part number from the part number column and combine with the desired option from the option column to form an order entry. Example 1: ACPL-772L-560E to order product of Gull Wing Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-2 Safety Approval in RoHS compliant. Example 2: ACPl-072L to order product of Small Outline SO-8 package in tube packaging and non RoHS compliant ...
Page 3
... MAX. 1.19 (0.047) MAX. 3.56 ± 0.13 (0.140 ± 0.005) 1.080 ± 0.320 0.65 (0.025) MAX. (0.043 ± 0.013) 2.54 ± 0.25 (0.100 ± 0.010) ACPL-772L Package with Gull Wing Surface Mount Option 300 9.65 ± 0.25 (0.380 ± 0.010 6.350 ± 0.25 (0.250 ± 0.010 ...
Page 4
... ACPL-072L Small Outline SO-8 Package 5.994 ± 0.203 (0.236 ± 0.008) XXXV 3.937 ± 0.127 YWW (0.155 ± 0.005 PIN ONE 0.406 ± 0.076 1.270 (0.016 ± 0.003) (0.050) * 5.080 ± 0.127 (0.200 ± 0.005) 3.175 ± 0.127 (0.125 ± ...
Page 5
... Note: Non-halide flux should be used Regulatory Information ACPL-072L has been approved while ACPL-772L is pending approval from the following organizations: IEC/EN/DIN EN 60747-5-2 Approved under: IEC 60747-5-2:1997 + A1:2002 EN 60747-5-2:2001 + A1:2002 DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01. ...
Page 6
... Creepage and clearance distances will also change depending on factors such as pollution degree and insulation level. 6 Symbol sec, Partial discharge < sec) V ini Value Symbol ACPL-772L ACPL-072L L(101) 7.1 4.9 L(102) 7.4 4.8 0.08 0.08 CTI >175 >175 IIIa IIIa ACPL-772L ACPL-072L Option 060 Option 060 I – ...
Page 7
Table 3. Absolute Maximum Ratings Parameter Storage Temperature [1] Ambient Operating Temperature Supply Voltages Input Voltage Output Voltage Average Output Current Lead Solder Temperature Solder Reflow Temperature Profile Table 4. Recommended Operating Conditions Parameter Ambient Operating Temperature Supply Voltages ( ...
Page 8
Table 6. Switching Specifications Test conditions that are not specified can be anywhere within the recommended operating range. The following specifications cover the following power supply combinations: (4.5V≤V (3V≤V ≤3.6V, 3V≤V ≤3.6V), (4.5V≤V DD1 DD2 All typical specifications are at ...
Page 9
... In accordance with UL1577, each ACPL-072L is proof tested by applying an insulation test voltage ≥ 4500 V ≤ 5 mA). Each ACPL-772L is proof tested by applying an insulation test voltage ≥ 4500 V current limit, I I-O ≤ 5 mA). limit, I I-O 11. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating. For the continuous voltage rating refers to your equipment level safety specification or Avago Technologies Application Note 1074 entitled “ ...
Page 10
... PWD can be expressed in percent by dividing the PWD (in ns) by the minimum pulse width (in ns) being transmitted. Typically, PWD on the order of 20-30% of the minimum pulse width is tolerable. The PWD specification for ACPL-x72L is 6ns (15%) maximum across recommended operating conditions 0.01 µ ...
Page 11
... The ACPL-x72L optocoupler offers the advantage of guaranteed specifications for propagation delays, pulse- width distortion, and propagation delay skew over the recommended temperature and power supply ranges. ...