FUNCTION DESCRIPTIONS
COMMANDS
“ HIGH” to “ LOW” state. If for some reason the STB pin is set to “ HIGH” while data or commands are being
transmitted, the serial communication is initialized, and the data/commands being transmitted are considered
invalid.
HANGZHOU SILAN MICROELECTRONICS CO.,LTD
Http: www.silan.com.cn
A command is the first byte (b0 to b7) inputted to SC16459 via the DIN pin after STB pin has changed from
Pin NO.
COMMAND 1: DISPLAY MODE SETTING COMMANDS
the first one byte data (b0 to b7) which is transmitted to SC16459 via the DIN pin when STB is “ LOW” .
However, for these commands, the bits 3 to bit 6 (b2 to b5) are ignored, the bits 7 & 8 (b6 to b7) are given a
value of “ 0”
duty, 14 to 11 segments). The display is forcibly turned off when these commands are executed. In order to
resume display, a display commands “ ON” must be executed. If the same mode setting is selected, no
command execution will be taken place, that is to say, nothing will happen.
COMMAND 2: DATA SETTING COMMANDS
bits 5 and 6 (b4, b5) are ignored, bit 7 (b6) is given the value of “ 1” while bit 8 (b7) is given the value of “ 0” .
Please refer to the diagram below.
22~25
21, 26
27, 28
The Data Setting Commands execute the Data Write Mode for SC16459. The Data Setting Command, the
When power is turned ON, bit 4 to bit 1 (b3 to b0) are given the value of “ 0” .
When power is turned “ ON” , the 7-Grid, 11-Segment mode is selected.
SC16459 provides 4 display mode settings as shown in the diagram below: As told above a command is
The display mode setting commands determine the number of segments and grids to be used (1/4 to 1/7
GND
GR4 to GR1
NC
Pin name
MSB
MSB
0
0
0
1
Relevant
Relevant
Not
-
-
Not
-
- b3 b2 b1 b0
Logic Ground pin.
Grid output pins (n-channel, open drain).
No connection
-
- b1 b0
LSB
LSB
Display mode settings:
00: 4 Grids, 14 Segments
01: 5 Grids, 13 Segments
10: 6 Grids, 12 Segments
11: 7 Grids, 11 Segments
Data write mode settings:
00: write data to display mode
Address increment mode settings (display mode):
0: increment address after data has been written
1: fixes address
Mode settings:
0: normal operation mode
1: test mode
Description
REV:1.1
SC16459
Page 3 of 8