en5311 Enpirion, en5311 Datasheet - Page 10

no-image

en5311

Manufacturer Part Number
en5311
Description
1a Synchronous Buck Regulator With Integrated Inductor
Manufacturer
Enpirion
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
en5311QI
Manufacturer:
ENPIRIO31
Quantity:
918
Part Number:
en5311QI
Manufacturer:
ALTERA
0
Part Number:
en5311QI
Manufacturer:
ENPIRION
Quantity:
20 000
Part Number:
en5311QI
0
Company:
Part Number:
en5311QI
Quantity:
850
Part Number:
en5311QI-E
Manufacturer:
ALTERA
0
Part Number:
en5311QI-T
Manufacturer:
ALTERA
0
March 2008
LAYOUT CONSIDERATIONS*
*Optimized PCB Layout file downloadable from the Enpirion Website to assure first pass design success.
Recommendation 1: Input and output filter capacitors should be placed as close to the EN5311QI
package as possible to reduce EMI from input and output loop AC currents. This reduces the
physical area of the Input and Output AC current loops.
Recommendation 2: DO NOT connect GND pins 3 and 4 together. Pin 3 should be used for the
Input capacitor local ground and pin 4 should be used for the output capacitor ground. The ground
pad for the input and output filter capacitors should be isolated ground islands and should be
connected to system ground as indicated in recommendation 3 and recommendation 5.
Recommendation 3: Multiple small vias (0.25mm after copper plating) should be used to connect
ground terminals of the Input capacitor and the output capacitor to the system ground plane. This
provides a low inductance path for the high-frequency AC currents; thereby reducing ripple and
suppressing EMI (see Fig. 5, Fig. 6, and Fig. 7).
Recommendation 4: The large thermal pad underneath the component must be connected to the
system ground plane through as many thermal vias as possible. The vias should use 0.33mm drill
size with minimum one ounce copper plating (0.035mm plating thickness). This provides the path for
heat dissipation from the converter.
Recommendation 5: The system ground plane referred to in recommendations 3 and 4 should be
the first layer immediately below the surface layer (PCB layer 2). This ground plane should be
continuous and un-interrupted below the converter and the input and output capacitors that carry
large AC currents.
uninterrupted ground “island” should be created on PCB layer 2 immediately underneath the
EN5311QI and its input and output capacitors. The vias that connect the input and output capacitor
grounds, and the thermal pad to the ground island, should continue through to the PCB GND layer as
well.
Recommendation 6: As with any switch-mode DC/DC converter, do not run sensitive signal or
control lines underneath the converter package.
Figure 5 shows an example schematic for the EN5311QI using the internal voltage select. In this
example, the device is set to a V
Figure 5. Example application, Vout=1.5V.
©Enpirion 2008 all rights reserved, E&OE
V
(see layout recommendation 3)
IN
ENABLE
VS2
VS1
VS0
4.7uF
17
18
19
20
If it is not possible to make PCB layer 2 a continuous ground plane, an
10µF
10
9
8
7
NC
NC
NC
V
OUT
OUT
of 1.5V (VS2=0, VS1=1, VS0=1).
V
OUT
Figure 6. Example Application, external divider, Vout = 2.6V.
(see layout recommendation 3)
V
IN
10
ENABLE
VS2
VS1
VS0
4.7uF
17
18
19
20
10µF
10
9
8
7
NC
NC
NC
V
OUT
www.enpirion.com
Ra=200K
Rb=60K
V
OUT
EN5311QI

Related parts for en5311