tfs70h313 Vectron International, Inc., tfs70h313 Datasheet

no-image

tfs70h313

Manufacturer Part Number
tfs70h313
Description
Vi Telefilter Filter
Manufacturer
Vectron International, Inc.
Datasheet
File name: Tfs70H313.doc
VI TELEFILTER
1. Measurement condition :
Ambient temperature T
Input power level:
Terminating impedances in f c *) :
2. Characteristics :
Remark:
minimum of the pass band attenuation a min is defined as the insertion loss a e . The reference frequency f c is the arithmetic mean value of
the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss a e . The temperature coefficient of frequency
Tc
shift of the filter in the operating temperature range is not included in the production tolerance scheme.
Data
Insertion loss (Reference level)
Centre frequency at ambient temperature (f
Pass band :
Amplitude ripple in :
Bandwidth at ambient temperature T
Relative attenuation :
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
Deviation from linear phase in PB :
Triple transit attenuation compared to main signal
Crosstalk
Temperature coefficient of frequency ( Tc
Frequency deviation of f c over temperature :
Operating temperature range
Storage temperature range
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information
10
20
40
f c ±
f c ± 11,75 MHz ... f c ± 15
f c ± 15
f
3
1
is valid both for the reference frequency f c and the frequency response of the filter in the operating temperature range. The frequency
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
Generated:
Checked/Approved:
dB
dB
dB
dB
dB
tft@telefilter.com
8,8 MHz ... f c ±
Reference level for the relative attenuation a rel of the TFS 70H313 is the minimum of the pass band attenuation a min . The
MHz ... f c ± 60
f c ... f c ±
A
:
f c ... f c ± 7,9 MHz
8,8 MHz
9,0 MHz
MHz
MHz
A
:
25
0
for input:
for output:
f
CTA
) :
°C.
dBm.
)
Dr. Bert Wall
Filter specification
a e
f c
PB
BW
a rel
Dr. Chilla
400
50
¸« -12,3 pF.
¸« 0 pF.
f c (Hz) = Tc
- 75
23
70,0
17,90
18,50
20,60
21,80
23,20
52
55
35
53
60
typ. value
0,4
1,21
-
-
f
(ppm/K) x (T - T
dB
dB
ns
dB
dB
MHz
MHz
MHz
MHz
MHz
MHz
dB
dB
µs
ppm/K
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail:
o
) x f
vti@vtinh.com
Version 1.1
TFS 70H313
CTA
(MHz)
tolerance / limit
max.
70,0 ± 0,1
f c ... f c ± 9
min.
min.
max.
max.
max.
min.
min.
max.
max.
- 25 °C ... + 80 °C
- 40 °C ... + 85 °C
26
17,6
18,0
23,5
40
47
60
1
3
6 °
15.04.2002
dB
MHz
MHz
MHz
MHz
dB
dB
dB
dB
ns
MHz
1/5

Related parts for tfs70h313

tfs70h313 Summary of contents

Page 1

... File name: Tfs70H313.doc VI TELEFILTER 1. Measurement condition : Ambient temperature Input power level: 0 Terminating impedances for input: for output: 2. Characteristics : Remark: Reference level for the relative attenuation a rel of the TFS 70H313 is the minimum of the pass band attenuation a min . The minimum of the pass band attenuation a min is defined as the insertion loss The reference frequency the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss a e ...

Page 2

... File name: Tfs70H313.doc VI TELEFILTER 3. Package and pin connection : 22,5 Max. 5,0 max. 5,6 max. 2,54 ± 0,2 6x2,54 = 15,62 TFS 70H313 P33 matching network ( details refer to application note ): Scheme 1. For final test we use scheme 1. VI TELEFILTER Potsdamer Straß 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 tft@telefilter ...

Page 3

... File name: Tfs70H313.doc VI TELEFILTER 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC Vibration 500 Hz, 0, respectively, 1 octave per min, 10 cycles per plan, 3 plans; ...

Page 4

... File name: Tfs70H313.doc VI TELEFILTER 6. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 °C - 170 °C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 Table for temperature vs. time during the air reflow process time / sec. temperature / ° ...

Page 5

... File name: Tfs70H313.doc VI TELEFILTER History Version Reason of changes 1.0 Generate preliminary specification . 1.1 Generate filter specification . add typical filter values; add matching networks: scheme 1; add termination impedances for scheme 1. referency frequency measurement changed from TELEFILTER Potsdamer Straß 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 tft@telefilter ...

Related keywords