adum1200-ep Analog Devices, Inc., adum1200-ep Datasheet - Page 8

no-image

adum1200-ep

Manufacturer Part Number
adum1200-ep
Description
Dual-channel Digital Isolator Adum1200-ep
Manufacturer
Analog Devices, Inc.
Datasheet
ADuM1200-EP
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)
Capacitance (Input-to-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
1
REGULATORY INFORMATION
The ADuM1200-EP is approved by the organizations listed in Table 5. See Table 10 for details regarding recommended maximum
working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL
Recognized Under 1577 Component
Single/Basic 2500 V rms Isolation Voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
The device is considered a 2-terminal device; Pin 1, Pin, 2, Pin 3, and Pin 4 are shorted together, and Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together.
In accordance with UL 1577, each ADuM1200WSRZ55 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection
limit = 5 μA).
In accordance with DIN V VDE V 0884-10, each ADuM1200WSRZ55 is proof tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge
detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
Recognition Program
1
1
1
CSA
Approved under CSA Component Acceptance
Notice #5A
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 400 V rms (566 peak) maximum
working voltage
Functional insulation per CSA 60950-1-03 and
IEC 60950-1, 800 V rms (1131 V peak) maximum
working voltage
File 205078
Symbol
L(I01)
L(I02)
CTI
Symbol
R
C
C
θ
θ
I-O
I-O
I
JCI
JCO
Rev. 0 | Page 8 of 16
Value
2500
4.90
4.01
0.017
>175
IIIa
Min
mm min
Unit
V rms
mm min
mm min
V
Typ
10
1.0
4.0
46
41
12
Conditions
1 minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Insulation distance through insulation
Max
Unit
Ω
pF
pF
°C/W
°C/W
VDE
Certified according to DIN V VDE
V 0884-10 (VDE V 0884-10): 2006-12
Reinforced insulation, 560 V peak
File 2471900-4880-0001
Test Conditions
f = 1 MHz
Thermocouple located at
center of package underside
2

Related parts for adum1200-ep