adum1100 Analog Devices, Inc., adum1100 Datasheet - Page 10

no-image

adum1100

Manufacturer Part Number
adum1100
Description
Icoupler Digital Isolator
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adum1100AR
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1100AR-RL7
Manufacturer:
STM
Quantity:
3 706
Part Number:
adum1100ARZ
Manufacturer:
ADI
Quantity:
5 000
Part Number:
adum1100ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
adum1100ARZ
Quantity:
10 000
Part Number:
adum1100ARZ-RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1100BR
Manufacturer:
TI
Quantity:
8
Part Number:
adum1100BR
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1100BR-RL7
Manufacturer:
TI
Quantity:
6 053
Part Number:
adum1100BRZ-RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuM1100
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 INSULATION CHARACTERISTICS
This isolator is suitable for reinforced isolation, only within the safety limit data. Maintenance of the safety data is ensured by means of
protective circuits. The * marking on the package denotes DIN V VDE V 0884-10 approval for 560 V peak working voltage.
Table 7.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
Highest Allowable Overvoltage
Safety-Limiting Values
Insulation Resistance at T
Figure 2. Thermal Derating Curve, Dependence of Safety-Limiting Value
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
After Environmental Tests Subgroup 1
After Input and/or Safety Test Subgroup 2 and Subgroup 3
Case Temperature
Side 1 Current
Side 2 Current
180
100
160
140
120
80
60
40
20
0
0
with Case Temperature per DIN V VDE V 0884-10
INPUT CURRENT
50
S
CASE TEMPERATURE (°C)
OUTPUT CURRENT
100
150
200
Conditions
V
t
V
discharge < 5 pC
V
discharge < 5 pC
Transient overvoltage, t
Maximum value allowed in the event of a
failure (see
V
m
IORM
IORM
IORM
IO
= 1 sec, partial discharge < 5 pC
Rev. G | Page 10 of 20
= 500 V
× 1.875 = V
× 1.6 = V
× 1.2 = V
Figure 2
PR
PR
, t
, t
PR
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter
Operating Temperature
Supply Voltages
Logic High Input Voltage,
Logic Low Input Voltage,
Logic High Input Voltage,
Logic Low Input Voltage,
Input Signal Rise and Fall Times
1
2
m
m
, 100% production test,
All voltages are relative to their respective ground.
Input switching thresholds have 300 mV of hysteresis. See the Method of
Operation, DC Correctness, and Magnetic Field Immunity section, Figure 19,
and Figure 20 for information on immunity to external magnetic fields.
= 60 sec, partial
= 60 sec, partial
)
ADuM1100AR/ADuM1100BR
ADuM1100UR
5 V Operation
(See Figure 11 and Figure 12)
5 V Operation
(See Figure 11 and Figure 12)
3.3 V Operation
(See Figure 11 and Figure 12)
3.3 V Operation
(See Figure 11 and Figure 12)
TR
= 10 seconds
1
1, 2
1, 2
1, 2
1, 2
Symbol
V
V
V
V
T
I
I
R
S1
S2
S
IORM
PR
PR
TR
S
Symbol
T
T
V
V
V
V
V
V
A
A
DD1
DD2
IH
IL
IH
IL
,
Characteristic
I to IV
I to III
I to II
40/105/21
2
560
1050
896
672
4000
150
160
170
>10
9
Min
−40
−40
3.0
2.0
0.0
1.5
0.0
Max
+105
+125
5.5
V
0.8
V
0.5
1.0
DD1
DD1
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Ω
Unit
°C
°C
V
V
V
V
V
ms