adum4400 Analog Devices, Inc., adum4400 Datasheet - Page 7

no-image

adum4400

Manufacturer Part Number
adum4400
Description
5 Kv Rms Quad-channel Digital Isolators
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adum4400ARWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum4400BRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum4400CRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
PACKAGE CHARACTERISTICS
Table 13.
Parameter
Resistance (Input to Output)
Capacitance (Input to Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
1
2
REGULATORY INFORMATION
The ADuM440x are approved by the organizations listed in Table 14. Refer to Table 19 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 14.
UL (Pending)
Recognized under 1577 component
recognition program
Double/reinforced insulation,
5000 V rms isolation voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 15.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Device considered a 2-terminal device: Pin 1, Pin 2, Pin 3, Pin 4, Pin 5, Pin 6, Pin 7, and Pin 8 shorted together and Pin 9, Pin 10, Pin 11, Pin 12, Pin 13, Pin 14, Pin 15, and
Pin 16 shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL 1577, each ADuM440x is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec (current leakage detection limit = 10 μA).
In accordance with DIN V VDE V 0884-10, each ADuM440x is proof tested by applying an insulation test voltage ≥1590 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
2
1
1
1
CSA (Pending)
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-03
and IEC 60950-1, 600 V rms (848 V peak)
maximum working voltage
Reinforced insulation per IEC 60601-1
250 V rms (353 V peak) maximum working
voltage
File 205078
Symbol
L(I01)
L(I02)
CTI
R
C
C
Symbol
θ
θ
I-O
I-O
I
JCI
JCO
Rev. 0 | Page 7 of 20
Value
5000
8.0 min
8.0 min
0.017 min
>175
IIIa
Min
Unit
V rms 1 minute duration
mm
mm
mm
V
Typ
10
2.2
4.0
33
28
12
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
ADuM4400/ADuM4401/ADuM4402
VDE (Pending)
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
Reinforced insulation, 846 V peak
File 2471900-4880-0001
Max
Unit
Ω
pF
pF
°C/W
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at
center of package underside
2

Related parts for adum4400