lm6060cby Topway Display, lm6060cby Datasheet - Page 6

no-image

lm6060cby

Manufacturer Part Number
lm6060cby
Description
Lcd Module User Manual
Manufacturer
Topway Display
Datasheet
3.3
3.3.1
Note:
*1. Input signal rise/fall time should be less than 15ns .
*2.All timing is using 20% and 80% of VDD as the reference.
URL:
Item
System cycle time
Address setup time (A0)
Address hold time (A0)
Control LOW pulse width (/RD)
Control LOW pulse width (/WR)
Control HIGH pulse width (/RD)
Control HIGH pulse width (/WR)
Data setup time
Data hold time
/RD access time (*2)
Output disable time (*2)
www.topwaydisplay.com
www.topwaysz.com
AC Characteristics
8080 Mode System Bus Timing
LCD Module User Manual
Symbol
tcchw
tacc8
tcyc8
tcclw
tcch
taw8
tah8
tdh8
tds8
tch8
tccl
r
r
MIN.
500
275
275
225
225
10
10
50
10
13
-
Document Name: LM6060CBY-Manual-Rev0.1.DOC
TYP.
-
-
-
-
-
-
-
-
-
-
-
V
SS
=0V, V
MAX.
175
125
-
-
-
-
-
-
-
-
-
DD
=3.0V, T
LM6060CBY
Page: 6 of 14
OP
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
=25°C