4. Function specifications
4.1
When the serial interface has been selected then when the chip is in active state the serial data
input(SI) and the serial clock(SCL) can be received. The serial data is read from the serial data
input pin in the rising edge of the serial clock . When “A0”=“H”, the data is display data, and when
“A0”=“L”, the data is command.
4.2
To drive the LCD module correctly and provide normally display, please use the following setting
Note:
*1. These setting/commands should issue the LCD module while start up.
*2. See the Display Commands section for details.
4.3
The LCD module should be initialized by using /RES terminal.
While turning on the VDD and VSS power supply, maintain /RES terminal at LOW level. After the
power supply stabilized, release the reset terminal (/RES=HIGH)
URL:
www.topwaydisplay.com
www.topwaysz.com
The Serial Interface
Basic Setting
Resetting the LCD module
-
-
-
-
-
-
-
-
ADC = 1 (reverse)
SHL select = 0 (normal)
LCD Bias Select = 1/9
Initial Display Line = 0
Entire Display ON/OFF = OFF (normal)
Reverse Display ON/OFF = OFF (normal)
Set Power Control Set:
Display ON/OFF = ON
voltage follower = ON, voltage converter = ON, voltage regulator = ON