afct-57m5atp ETC-unknow, afct-57m5atp Datasheet - Page 6

no-image

afct-57m5atp

Manufacturer Part Number
afct-57m5atp
Description
2/1/1 Gbd Sfp Transceiver For Fibre Channel And Gbe, Digital Diagnostic, Ext Temp -10c To +85c
Manufacturer
ETC-unknow
Datasheet
Table 2. Pin Description
Notes:
1. TX_FAULT is an open collector/drain output, which should be pulled up with a 4.7 k – 10 kW resistor on the host board. When high, this output
2. TX_DISABLE is an input that is used to shut down the transmitter optical output. It is pulled up within the transceiver with a 4.7 k – 10 kW resistor.
3. The signals Mod-Def 0, 1, 2 designate the two wire serial interface pins. They should be pulled up with a 4.7 k – 10 kW resistor on the host board.
4. RX_LOS (Rx Loss of Signal) is an open collector/drain output that should be pulled up with a 4.7 k – 10 kW resistor on the host board. When high, this
5. RD-/+ designate the differential receiver outputs. They are ac coupled 100 W differential lines which should be terminated with 100 W differential at
6. V
7. TD-/+ designate the differential transmitter inputs. They are ac coupled differential lines with 100 W differential termination inside the module. The
6
Pin
1
2
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
3
4
indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.4 V.
Low (0 – 0.8 V):
Between (0.8 V and 2.0 V):
High (2.0 – V
Open:
Mod-Def 0 is grounded by the module to indicate the module is present
Mod-Def 1 is clock line (SCL) of two wire serial interface
Mod-Def 2 is data line (SDA) of two wire serial interface
output indicates the received optical power is below the worst case receiver sensitivity (as defined by the standard in use). Low indicates normal
operation. In the low state, the output will be pulled to < 0.8 V.
the host SerDes. Ac coupling is done inside the transceiver and is not required on the host board. The voltage swing on these lines will be between
450 and 2000 mV differential (225 – 1000 mV single ended) when properly terminated.
and the associated inrush current will typically be no more than 30 mA above steady state after 500 nanoseconds.
ac coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 350 – 2400 mV (175 –
1200 mV single ended).
CC
R and V
CC
CC
T are the receiver and transmitter power supplies. They are defined at the SFP connector pin. The maximum supply current is 300 mA
max):
Name
MOD-DEF2
MOD-DEF1
MOD-DEF0
RX_LOS
RD-
RD+
V
TX_FAULT
TX_DISABLE
V
V
V
V
V
V
V
TD+
TD-
V
EE
EE
EE
EE
EE
CC
CC
EE
EE
T
R
R
R
R
R
T
T
T
Transmitter on
Undefined
Transmitter Disabled
Transmitter Disabled
Function/Description
Module Definition 2 - Two Wire Serial ID Interface Data Line (SDA)
Module Definition 1 - Two Wire Serial ID Interface Clock Line (SCL)
Module Definition 0 - Grounded in Module (module present indicator)
Reserved
Loss of Signal - High indicates loss of received optical signal
Receiver Ground
Receiver Ground
Receiver Ground
Inverse Received Data Out
Received Data Out
Receiver Ground
Receiver Power +3.3 V
Inverse Transmitter Data In
Transmitter Ground
Transmitter Fault Indication - High indicates a fault condition
Transmitter Disable - Module optical output disables on high or open
Transmitter Power +3.3 V
Transmitter Ground
Transmitter Data In
Transmitter Ground
MSA Notes
1
2
3
3
3
5
5
6
6
7
7
4

Related parts for afct-57m5atp