hrpg-150 Mean Well Enterprises Co., Ltd., hrpg-150 Datasheet - Page 3

no-image

hrpg-150

Manufacturer Part Number
hrpg-150
Description
150w Single Output With Pfc Function
Manufacturer
Mean Well Enterprises Co., Ltd.
Datasheet
1.Remote Control
2.Remote Sense
The remote sensing compensates voltage drop on the
Function Description of CN100
Function Manual
The PSU can be turned ON/OFF by using the "Remote
ON/OFF" function
load wiring up to 0.5V.
Between RC-(pin5) and RC+(pin6)
SW ON (Short)
SW OFF (Open)
Pin No. Function Description
1
2
3
4
5
6
AUXG
AUX
RC+
RC-
+S
-S
150W Single Output with PFC Function
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
Auxiliary voltage output, 4.6~5.25V, referenced to pin 3(AUXG). The maximum load current is 0.3A. This output has the built-in oring
diodes and is not controlled by the "remote ON/OFF control".
Remote control ground.
Turns the output on and off by electrical or dry contact between pin 5 (RC-). Short: Power OFF, Open: Power ON.
Output Status
OFF
ON
(Pin1)
-S
-V
-V
-
-
-V
-V
Fig 1.1
Fig 2.1
LOAD
LOAD
+V
+V
+
+
+V
+V
+S
(Pin2)
CN100
CN100
Sense lines should
be twisted in pairs
6 4 2
5 3 1
6 4 2
5 3 1
H R P G - 1 5 0
6
5
6
5
RC+
RC+
RC-
RC-
CN100
AUXG
CN100
AUXG
AUX
AUX
File Name:HRPG-150-SPEC 2009-07-27
+S
+S
-S
-S
2
1
2
1
SW
s e r i e s

Related parts for hrpg-150