ESD Protection
Human Body Model (HBM) tests according to:
Standard EIA/JESD22-A114-B HBM (covers MIL STD 883D)
Parameter
ESD-Protection
TLE4953C
TLE4953
Operating Range
Parameter
Supply voltage
Supply voltage
Supply voltage ripple
Junction temperature
Pre-induction
Pre-induction offset
between outer probes
Pre-induction offset
between mean of outer
probes and center probe
Differential Induction
1) Reduced performance possible for jitter/phase accuracy and power supply rejection ratio (EMC). Current levels will
2) increased jitter and reduced phase accuracy permissible between 150 and 170°C junction temperature.
Note: Within the operating range the functions given in the circuit description are fulfilled.
Data Sheet
typically decrease but will be within specification limits. This voltage range is not recommended for continuos operation
and should cover the function during short voltage drops which may occur at cranking of engine / test pulse 4.
Symbol
V
Symbol
V
V
V
T
B
m/o
B
j
B
B
ESD
CC
CC
AC
0
stat.,
stat., l/r
min.
4.5
4.0
– 40
– 500
– 20
– 20
– 120
min.
-
-
Limit Values
Limit Values
8
max.
20
4.5
6
150
170
+ 500
+ 20
+ 20
+ 120
max.
± 12
± 12
Unit
V
V
Vpp
°C
mT
mT
mT
mT
Unit
kV
Remarks
Directly on IC leads
excludes the
drop
Directly on IC leads
excludes the
drop
V
0 ≤
168h V
L-R
(L+R)/2-C
CC
f
= 13 V
1)
≤ 50 kHz
Notes
R
C
CC
= 1.5 kΩ,
= 100 pF
≤ 16.5 V
V 2.0, 2007-02
TLE4953C
R
R
TLE4953
M
M
voltage
voltage
2)