mpe-40s MicroPower Direct, LLC, mpe-40s Datasheet

no-image

mpe-40s

Manufacturer Part Number
mpe-40s
Description
Single Output, 40w Compact, Enclosed Ac/dc Power Supplies
Manufacturer
MicroPower Direct, LLC
Datasheet
MPE-40S
Key Features:
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Single Output, 40W
Compact, Enclosed
AC/DC Power Supplies
40W Output Power
Universal 85-264 AC Input
EN 60950 Approved
Four Single Output Models
Meets EN55022
>300 kHour MTBF
Compact Metal Enclosure
Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Parameter
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz) , See Note 2
Hold-Up Time
Set-Up Time
Rise Time
Temperature Coeffi cient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Safety Ground Leakage Current
Output
General
Parameter
Isolation Voltage
Isolation resistance
EMI/RFI
EMC Compliance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifi cations
Parameter
MTBF
Safety Standards
Vibration
www.micropowerdirect.com
Series
Electrical Fast Transients/Bursts On Mains
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
MIL HDBK 217F, 25°C, Gnd Benign
Electrostatic Discharge (ESD)
Conditions
Conditions
Conditions
Conditions
Conditions
RF Field Susceptibility
RH, Non-condensing
Cold Start, 115 VAC
Cold Start, 230 VAC
Free Air Convection (See Derating Curve)
Output to Ground
Input to Ground
Input to Output
5.18 x 3.93 x 1.53 Inches (131.6 x 100.0 x 38.0 mm)
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
Continuous (Autorecovery)
Conducted
See Note 3
See Note 4
IEN 60950, IEC 60950
Universal
500 VDC
115 VAC
230 VAC
115 VAC
230 VAC
115 VAC
230 VAC
115 VAC
230 VAC
Ambient
Surge
3,000
1,500
Min.
Min.
Min.
Min.
Min.
115
110
120
500
300
-10
-20
85
47
20
IEC/EN 61000-4-2, -6, -8, -11
EN 55022; EN 61000-3-2, -3
±0.02
IEC/EN 61000-4-4
IEC/EN 61000-4-5
Typ.
30.0
60.0
Typ.
Typ.
IEC/EN61000-4-3
Typ.
Typ.
+25
800
300
100
15
60
50
50
36
Vented Metal Enclosure
Max.
Max.
Max.
Max.
Max.
135
160
+60
+85
264
370
0.6
1.0
63
90
15.4 Oz (0.44 kg)
% Vout
kHours
% Iout
Units
Units
mSec
mSec
mSec
%/°C
Units
Units
Units
VDC
A Pk
VAC
VAC
kHz
M
mA
Hz
°C
°C
%

Related parts for mpe-40s

mpe-40s Summary of contents

Page 1

... MPE-40S Single Output, 40W Compact, Enclosed AC/DC Power Supplies Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Key Features: Input Parameter • 40W Output Power • ...

Page 2

... The unit recovers automatically when the fault condition is removed. 5. Effi ciency is measured with a 115 VAC input recommended that a fuse be used on the input of a power supply for protection. For the MPE-40S series, a 2.5A/250 VAC slow blow should be used. Pin Connections Pin ...