ws12-2500-10v-l10-m4-m12 ASM GmbH, ws12-2500-10v-l10-m4-m12 Datasheet - Page 11

no-image

ws12-2500-10v-l10-m4-m12

Manufacturer Part Number
ws12-2500-10v-l10-m4-m12
Description
Posiwire Ws12 Analog, Ssi Or Canopen Output
Manufacturer
ASM GmbH
POSIWIRE
ADSI16
A/D Converted SSI Output
66
Description
Data format
(train of 26 pulses)
Recommended
processing circuit
Signal conditioner
ADSI16
A/D converted
synchronous serial
Transmission rate
Signal wiring
CAT-WS-US-09
®
The sensing device of the ADSI is a precision potentiometer. The position information is given
by an analog/digital converter output serialized as a data word. Data transmission takes
place by means of the signals CLOCK and DATA. The processing unit (PLC, Micro- com-
puter) sends pulse sequences which clock the data transmission with the required transfer
rate. With the first falling edge of a pulse sequence the position of the sensor is recorded and
stored. The following rising edges control the bit-by-bit A/D conversion, encoding and output
of the data word. After a delay time the next new position information will be transmitted.
Interface
Excitation voltage
Excitation current
Clock frequency
Code
Delay between pulse trains
Resolution
Stability (temperature)
Operating temperature
EMC
Cable length
< 164 ft. (50 m)
< 328 ft. (100 m)
Signal name
Excitation +
Excitation GND (0 V)
CLOCK
CLOCK
DATA
DATA
Shield
Resolution 16 bit, synchronous serial data transmission/SSI
Optional available with 12 bit (ADSI) or 14 bit (ADSI14) resolution
No loss of data at power down
Easy to connect to PLC´s with SSI input circuitry
1-888-ASM-USA-1 • www.asmsensors.com
Sensor circuit
DATA
DATA
Connector pin no.
not connected
< 300 kHz
< 100 kHz
Baud rate
Cable
1
2
3
4
5
6
Subsequent circuit
EIA RS422, RS485, short-circuit proof
11 ... 27 V DC
200 mA max.
70 ... 500 kHz
Gray code, continuous progression
30 µs min.
16 bit (65536 counts) f.s.;
optional 12 (ADSI) bit resp. 14 bit (ADSI14)
±28 x 10
-4 ... +185 °F
According to EN 61326:2006
Note:
Extension of the cable length will reduce
the maximum transmission rate.
CLOCK
CLOCK
GND (0 V)
-6
/ °F f.s.
CONN-M12-8F
ASM Sensors, Inc.
View to sensor
connector