cpm2c Omron Corporation, cpm2c Datasheet - Page 3

no-image

cpm2c

Manufacturer Part Number
cpm2c
Description
Programmable Slaves
Manufacturer
Omron Corporation
Datasheet
Communications Specifications
● DeviceNet
*1.
*2.
Cables for I/O Connector
● Cables for Connector - Terminal Conversion Units
96
Communications
protocol
Connection form
*1
Baud rate
Communications
media
Communications
distance
Communications
power supply
Maximum number
of nodes
XW2Z-@@@A
Terminating resistance is required at both ends of the trunk line.
This value applies when using Thick Cable for the trunk line.
If Thin Cable is used, the value will be 100 m max.
Cable
Item
Programmable Slaves
Conforms to DeviceNet
Combination of multi-drop method and T-branch connections
(for trunk and drop lines)
500, 250, or 125 kbps
Special 5-wire cable (2 signal lines, 2 power supply lines,
1 shield line)
4-wire Special Flat Cable (2 signal lines and 2 power lines)
24 VDC is supplied externally.
64 (including Masters, Slaves, and the Configurator)
• Using special 5-wire Flat Cable
• Using special 4-wire Flat Cable
Baud rate
Baud rate
500 kbps
250 kbps
125 kbps
500 kbps
250 kbps
125 kbps
XW2D-20G6
XW2B-20G4
Connected
product
100 m max. *2
250 m max. *2
500 m max. *2
Network length
Network length
150 m max.
265 m max.
75 m max.
(max.)
(max.)
Slim type
(with M3-screw terminal block)
Flat cable connector type
(with M3 (minus) terminal block)
For detailed specifications, refer to the user’s manual (Cat. No. W377).
Specifications
CPM2C-S1@0C-DRT
Branch line
Branch line
6 m max.
6 m max.
6 m max.
6 m max.
6 m max.
6 m max.
Remarks
length
length
Total branch
Total branch
156 m max.
135 m max.
line length
39 m max.
78 m max.
line length
35 m max.
48 m max.
● CompoBus/S
*1.
*2.
*3.
*4.
Dimensions
CPM2C-S100C-DRT
CPM2C-S110C-DRT
Communications
protocol
Coding method
Connection form
Baud rate
Com-
muni-
cations
cycle
time
Communications
media
Communications
distance
Maximum number
of nodes
Error control
checks
Connect external terminating resistance.
Switched using DM area setting. (Default setting: 750 kbps.)
If the number of slaves connected is 16 or less, the maximum main line length
will be 100 m max., and the maximum total branch line length will be 50 m max.
There are no restrictions on the branching configuration, main line length,
branch line length, or total branch line length. Connect external terminating
resistance to the node farthest from the master.
Item
High-
speed
Commu-
nications
Mode
Long-dis-
tance
Commu-
nications
Mode
40
Special CompoBus/S protocol
Manchester coding
Multi-drop method and T-branch connections *1
High-speed Communications Mode: 750 kbps
Long-distance Communications Mode: 93.75 kbps *2
0.5 ms (with 8 input and 8 output slaves connected)
0.8 ms (with 16 input and 16 output slaves connected)
4.0 ms (with 8 input and 8 output slaves connected)
6.0 ms (with 16 input and 16 output slaves connected)
2-wire cable (VCTF 0.75 x 2),
4-wire cable (VCTF 0.75 x 4), or Special Flat Cable
32
Manchester code check, frame length check, and parity check
• 2-wire VCTF cable
• 4-wire VCTF cable or Special Flat Cable
High-speed
Communications
Mode
Long-distance
Communications
Mode
High-speed
Communications
Mode *3
Long-distance
Communications
Mode *4
Communications
Communications
mode
mode
90
Free branching
(up to a total cable length of 200 m)
100 m max.
500 m max.
30 m max.
Main line
Main line
Specifications
length
length
Branch line
Branch line
(77)
3 m max.
6 m max.
3 m max.
length
length
65
Total branch
Total branch
line length
50 m max.
line length
30 m max.
120 m
(Unit: mm)
max.

Related parts for cpm2c