ms4525do Measurement Specialties, ms4525do Datasheet - Page 5

no-image

ms4525do

Manufacturer Part Number
ms4525do
Description
Pcb Mounted Pressure Transducers
Manufacturer
Measurement Specialties
Datasheet
MS4525DO
PACKAGE, PINOUT, AND PRESSURE TYPE CONFIGURATION
Prange is equal to the maximum full scale pressure specified in the ordering information.
Wetted Material by Port Designation
MS4525DO
Pin Name
GND
SUPPLY
SDA
SCL
INT
Pressure Type
Absolute
Differential/
Bidirectional
Gauge
Compound
"X" Indicates Wetted Material
INT/SS
INT/SS
DS, MM
PORT 2
SS, TP
Style
4525DO-DSvxxxyP
5
6
7
8
5
6
7
8
SCLK
MISO
SS
PORT 1
Pmin
0psiA
-Prange
0psiG
-15psiG
Port
Port 1
Port 2
Port 1
Pin
1
2
3
4
5
1
4
3
2
1
4
3
2
PORT 1
SCL/SCLK
SDA/MISO
GND
SUPPLY
Pmax
+Prange
+Prange
+Prange
+Prange
Ceramic
SCL/SCLK
SDA/MISO
SUPPLY
GND
Function
Ground
Positive Supply Voltage
I2C Data
I2C Clock
I2C Interrupt
X
X
X
INT/SS
INT/SS
Description
Output is proportional to the difference between 0psiA (Pmin) and pressure
applied to Port 1.
Output is proportional to the difference between Port 1 and Port 2. Output
swings positive when Port 1> Port 2. Output is 50% of total counts when
Port 1=Port 2.
Output is proportional to the difference between 0psiG (Pmin) and Port 1.
Output swings positive when Port 1> Port 2.
Output is proportional to the difference between -15psiG pressure (Pmin)
and pressure applied to Port 1.
PORT 2
Silicon
X
X
X
5
6
7
8
5
6
7
8
www.meas-spec.com
SPI Chip Select
PORT 1
Pyrex
5/17
X
X
X
SPI Data
SPI Clock
4
3
2
1
1
4
3
2
SCL/SCLK
SDA/MISO
GND
SUPPLY
RTV
Material
X
X
X
SCL/SCLK
SDA/MISO
SUPPLY
GND
Gold
X
X
INT/SS
INT/SS
PORT 2
Aluminum
5
6
7
8
5
6
7
8
X
X
PORT 1
1
1
4
3
2
4
3
2
SCL/SCLK
SDA/MISO
GND
SUPPLY
SCL/SCLK
January 2011
SDA/MISO
GND
SUPPLY
IDENTIFIER
Epoxy
X
X
X

Related parts for ms4525do