Additional features and protections
5
5.1
10/14
Additional features and protections
Output overvoltage protection
The overvoltage protection, OVP, is realized by using an internal comparator, whose input is
connected to the feedback. It turns off the power stage when the OVP threshold is reached.
This threshold is typically 30 % higher than the feedback voltage.
Figure 6.
Figure 4.
Vin
Vin
GS-RxxFp000z.z
4, 5
Multiple units synchronization
Output voltage programming
4, 5
GS-RxxFpyyyz.z
6, 7
6, 7
8, 9
10
8, 9
Rv
2
Rload
Rload
Figure 5.
Vin
Vin
4, 5
GS-RxxFpyyyz.z
4, 5
GS-RxxFp000z.z
Loop compensation
6, 7
6, 7
8, 9
2
8, 9
10
Rload
Rv
GS-R12FP
Cc
Rload