a2si-mt ETC-unknow, a2si-mt Datasheet

no-image

a2si-mt

Manufacturer Part Number
a2si-mt
Description
Release Notes Revision
Manufacturer
ETC-unknow
Datasheet
Technical Upgrades in A²SI Revision C
Release Notes, A²SI Revision C, August 28, 2002
Effected part of the A²SI
Infrared input channel
Slave Mode
Effected part of the A²SI
UART
Telegram Checker
UART
Master Mode
Main State Machine
Slave Mode
Communication Watchdog
Oscillator
Description of modification
It appeared the infrared input channel (IRD) was sensitive against
coupled noise in some application circuits. In order to make the
photo current input more robust for a broad variety of designs, the
analog receiver circuit had been changed. This resulted in a
much better performance in terms of noise sensitivity but required
a slightly lower signal sensitivity as well. See the updated Data
Sheet for more information.
Description of modification
The telegram reception under worst case capacitive and worst
case inductive network conditions was improved in response to
suggestions of the technical committee of the AS-International
Association.
The digital MAN-code communication channel does now support
a more cost effective two-wire data transfer between the A²SI
and the master control logic. It is not necessary to rely on the
additional ‘Receive_Strobe’ signal, which is supplied at the pa-
rameter port P2 in Master Mode to verify the correctness of the
MAN output signal at the LED port.
The MAN signal is now distinctively disturbed if an erroneous
telegram was detected at the AS-i input. This allows to spare at
least one opto coupler in between the A²SI and the master con-
trol.
If running, the communication watchdog will now become turned
off as soon as the volatile slave address register is changed to
zero (0x0). This occurs after the reception of a Delete_Address
call or at a reset of the A²SI.
In all previous revisions, a running communication watchdog
could only be turned off by a reset of the A²SI (reception of Re-
set_Slave call or external reset).
In case the watchdog was running and a master did not submit a
Reset_Slave call prior to an address assignment, the write ac-
cess to the non-volatile E²PROM memory could have been inter-
rupted. Because a data corruption is likely in such an event, the
A²SI resumed to the fail save state of slave address zero (0x0)
and did not respond to the newly assigned address until the ad-
dress assignment call was repeated.
The loop gain of the oscillator was increased to support a
broader variety of 8MHz crystals.
ZMD AG
Release Notes, IC Revision C
A²SI
1/4

Related parts for a2si-mt

a2si-mt Summary of contents

Page 1

Technical Upgrades in A²SI Revision C Effected part of the A²SI UART Telegram Checker UART Master Mode Main State Machine Slave Mode Communication Watchdog Oscillator Effected part of the A²SI Infrared input channel Slave Mode Release Notes, A²SI Revision C, ...

Page 2

The replacement of A²SI Revision B with Revision C neither has any impact to required external components nor requires a change of the external circuitry. The CAP-Pin Revision C shall be connected to a series of ...

Page 3

... Ordering Information Ordering Description Code A2SI-ST Standard version of A²SI A2SI-SR Standard version of A²SI A2SI-MT Pre-programmed master function A2SI-MR Pre-programmed master function Sales Contacts Sales Office Dresden Zentrum Mikroelektronik Dresden AG Grenzstraße 28 D-01109 Dresden Germany Phone +49-351-8822-310 Fax +49-351-8822-337 sales@zmd.de ...

Page 4

Trademark: A²SI™ trademark of AMI Semiconductor, Inc. Life Support Policy ZMD products are not designed, intended, or authorised for use as components in systems intended for surgical implant into the body, or other applications intended to support or ...