sdc25 Yamatake Corporation, sdc25 Datasheet - Page 12

no-image

sdc25

Manufacturer Part Number
sdc25
Description
Single Loop Controller
Manufacturer
Yamatake Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SDC25
Manufacturer:
AZBIL/YAMATAKE
Quantity:
1 000
G Precautions on the use of self-tuning function
G Precautions on wiring
1. Isolation within instrument
Availability of input and output is based on a model number.
Note 1 In case of independent contact, the part between the event
2. Preventive measures against noise of instru-
Power supply
PV input
Current Transformer input 1
Current Transformer input 2
Loader communication
Digital input 1
Digital input 2
Digital input 3
Digital input 4
RS-485 Communication
This product has been designed, developed and manufactured for general-purpose application in machinery and equipment.
Accordingly, when used in the applications outlined below, special care should be taken to implement a fail-safe and/or redundant
design concept as well as a periodic maintenance program.
Never use this product in applications where human safety may be put at risk.
(1) Reduction of noise
• Safety devices for plant worker protection • Start/stop control devices for transportation and material handling machines
• Aeronautical/aerospace machines
The final control devices must be powered up simul-
taneously with or prior to the instrument when the
self-tuning function is to be used.
Solid line portions "
Dotted line portions "
ment power supply
Specifications are subject to change without notice.
Advanced Automation Company
1-12-2 Kawana, Fujisawa
Kanagawa 251-8522 Japan
URL: http://www.azbil.com
output 1 and the event output 2 is isolated.
Even though the noise is small, the noise filter is used
to eliminate the effect of the noise as much as possible.
Instrument power supply
100 to 240Vac
" are isolated.
Internal
Circuit
" are not isolated.
Noise filter
Control output 1
Control output 2
Auxiliary output
Event output 1 (Note 1)
Event output 2 (Note 1)
Event output 3
• Control devices for nuclear reactors
RESTRICTIONS ON USE
C25
1
2
C26
1
2
12
3. Installation environment noise sources and
Preventive measures against fast rise noise
4. Wiring precautions
5. Inspection after wiring
(2) When noise is excessive
(1) After taking the noise preventive measures, do not
(2) Keep the input/output and communication lines 50 cm
preventive measures
Generally, the following may be the noise sources in the
installation environment:
Relay and contact, electromagnetic coil, solenoid valve,
power supply line (particularly, 100Vac or more), motor
commutator, phase angle control SCR, radio communica-
tion device, welding machine, high-voltage ignitor, etc.
Use of CR filter is effective to prevent fast rise noise.
After the wiring work has been completed, always
inspect and check the wiring status. Great care should
be taken since incorrect wiring may cause the instru-
ment to malfunction or severe personal injury.
Instrument
power supply
100 to 240Vac
If a large amount of noise exists, appropriate isolation
transformer and line filter are used to eliminate the
effect of the noise.
Recommended filter:
bundle the primary and secondary power cables together
or put both power cables in the same conduit or duct.
or more away from the power lines and power supply
lines having a voltage of 100Vac or more.
Additionally, do not put these lines together in the same
conduit or duct.
Other circuit
Yamatake's model No. 81446365-001
(Equivalent to 953M500333311 made by Matsuo
Electric.)
No part of this publication may be reproduced or duplicated
without the prior written permission of Yamatake Corporation.
Insulation
transformer
(100/100V)
(200/200V)
Grounding
Line filter
Yamatake's model No.
(Equivalent to ZAC2205-00U
made by TDK)
1st Edition: Issued in Jan., 2004
E81446364-001
1
E
2
GND
3
4
Printed in Japan. (H)
C25
1
2
C26
1
2