cxm3580ur Sony Electronics, cxm3580ur Datasheet
cxm3580ur
Related parts for cxm3580ur
cxm3580ur Summary of contents
Page 1
... The CXM3580UR is a SP4T+ SP5T antenna switch module for GSM/UMTS/CDMA /LTE multi-mode handset. The CXM3580UR has a built-in dual low pass filter and a +1.8 V CMOS compatible decoder. The Sony GaAs Junction gate pHEMT (JPHEMT) MMIC process is used for low insertion loss and high linearity ...
Page 2
Absolute Maximum Ratings ( Bias voltage Control voltage Input power max. (Tx1) Input power max. (Tx2) Input power max. (TRx) Input power max. (Rx) Operating temperature range Storage temperature range Vctl 4 ...
Page 3
Block Diagram SP4T + SP5T Antenna Switvh Module Ant (L) Ant (H) SP4T + SP5T 3TRx/2Tx/4Rx Decoder Logic - 3 - Tx1 Rx1 Rx2 TRx1 Tx2 Rx3 Rx4 TRx3 TRx4 ...
Page 4
Truth Table CTL Sate State Active Path CTLA CTLB CTLC CTLD 1 Tx1-ANT ( Tx2-ANT ( Rx1-ANT ( Rx2-ANT ( TRx3-ANT ( ...
Page 5
Pin Configuration GND Rx1 GND Rx2 TRx3 Rx4 TRx1 GND DC Bias Conditions ( Item Min. V 2.5 DD Vctl (H) 1.35 Vctl ( UQFN-26P PKG (2.6 ...
Page 6
Electrical Characteristics 2 Item Symbol Insertion loss IL VSWR VSWR 2fo 3fo 2fo Harmonics 3fo 2fo 3fo Attenuation ATT Inter IMD2 modulation product power IMD3 in Rx band Input IP3 IP3 ...
Page 7
Item Symbol Ant (L) – Ant (H) (TRx1 Active) TRx1 – TRx3, TRx4 (TRx1 Active) TRx1 – Rx1, Rx2, Rx3 (TRx1 Active) TRx1 – Rx4 (TRx1 Active) Ant (H) – Ant (L) (TRx3 Active) TRx3 – TRx1, TRx4 (TRx3 Active) ...
Page 8
Item Symbol Ant (H) (Tx2 Active) Tx2 (Tx2 Active) Tx2 Isolation ISO (Tx2 Active) Tx2 (Tx2 Active) Tx2 (Tx2 Active) Electrical characteristics are measured with all RF ports terminated in 50 Ω. Corresponding Band of GSM Tx/Rx (GSM). *1 Pin ...
Page 9
IMD Condition fRx Band on TRx +20dBm on TRx Band I 2140 MHz 1950 MHz Band II 1960 MHz 1880 MHz Band V 880 MHz 835 MHz IIP3 Condition f1 Band +27 dBm on TRx Band I 1950 MHz Band ...
Page 10
Triple Beat Ratio 2 Item Symbol Path Triple Beat TBR Ratio Ant- TRx1,3, 4 Electrical characteristics are measured with all RF ports terminated in 50 . *1 Measured with the recommended ...
Page 11
Recommended Circuit GND Rx1 GND Rx2 TRx3 Rx4 TRx1 GND Note blocking capacitors are required on all RF ports levels of all RF ports are GND (22 nH) and C1 (56 pF) are ...
Page 12
Recommended Land Pattern PKG: 3.4 mm × 2.6 mm Pin pitch: 0.4 mm 3.6 3.4 (PKG Line) 2.5 (∗) 0.8 0.6 PCB GND Design for UQFN-26P (Image) Metal mask thickness: 110 µm : Metal area in board ( ∗ 1 ...
Page 13
Package Outline (Unit: mm Sony Corporation ...