VSK-S3-XXU CUI [CUI INC], VSK-S3-XXU Datasheet - Page 3

no-image

VSK-S3-XXU

Manufacturer Part Number
VSK-S3-XXU
Description
ac-dc converter
Manufacturer
CUI [CUI INC]
Datasheet
PART NUMBER: VSK-S3-XXU series
TYPICAL EFFICIENCY CURVE
TYPICAL EFFICIENCY CURVE
L
N
1. Output filtering capacitors C1, C3 is electrolytic capacitors, It is recommended to use high frequency and low impedance electrolytic capacitors. For
2. MOV is required for VSK-S3 models. Model: 471KD05, it is used to protect the device under surge.
3. It is recommended to connect FUSE, the parameter is 0.5A/250V slow blow. External input NTC is recommended to use
4. If EMC performance is required, recommended to add “EMC filter” at the input end(see figure 2)
5. Terminals 22 and 26 are internal rectification and filtering terminals. To protect the models further, it is recommended to connect an electrolytic
* FUS E
Note!
capacitor C3 (it is recommended to be 4.7uF/400V). If operation voltage of the module is between 160~264VAC, C3 can be removed.
D -14 or 10Ω/2W wire-round resistor.
capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C2, C4 is ceramic
capacitors , it is used to filter high frequency noise. TVS is a recommended component to protect post-circuits (when converter fails).
C6:X capacitor, recommended parameter 0.1uF/275V;
C7,C8:Y capacitor, recommended parameter 220pF/2000V;
NF: common model choke, recommended inductance is about 10mH-30mH.
20050 SW 112
VSK-S3-3R3U
VSK-S3-12U
VSK-S3-15U
VSK-S3-24U
VSK-S3-5U
VSK-S3-9U
M OV
model
* NT C
+
C 3
th
L
2 2
2 6
N
Ave. Tualatin, Oregon 97062
Figure1
+V0
- V0
C 1
150
150
150
150
150
150
C1
+
EXTERNAL CAPACITORS TYPICAL VALUE(Unit: µF)
C 2
T v s
R L
phone
phone 503.612.2300 fax
C2
0.1
0.1
0.1
0.1
0.1
0.1
DESCRIPTION: ac-dc converter
TYPICAL EFFICIENCY CURVE
N
L
* F USE
Fuse
* NT C
C3
Figure 2
C 6
NF
3
fax 503.612.2382
4.7/400V
4.7/400V
4.7/400V
4.7/400V
4.7/400V
4.7/400V
C 7
C8
VSK-S3 EMC
C3
MO V
C 3
25.4mm
+
C1
Application Figure
Connect Oscillograph probe
L
26
N
22
+V0
-V0
C2
rev.
page
date
25.4mm
P4KE6.8A
P4KE6.8A
P4KE12A
P4KE20A
P4KE20A
P4KE30A
TVS
C 1 C 2
+
Copper sheet
06/2008
3 of 4
T v s
Load
R L