MDC_UCE MURATA [Murata Manufacturing Co., Ltd.], MDC_UCE Datasheet - Page 11

no-image

MDC_UCE

Manufacturer Part Number
MDC_UCE
Description
Isolated, High-Density, Eighth-Brick 100W DC/DC Converters
Manufacturer
MURATA [Murata Manufacturing Co., Ltd.]
Datasheet
Remote On/Off Control
On the input side, a remote On/Off Control can be ordered with either polarity.
is pulled high to +Vin with respect to –Vin. An internal bias current causes
the open pin to rise to approximately +15V. Some models will also turn on at
lower intermediate voltages (see Specifi cations). Positive-polarity devices are
disabled when the On/Off is grounded or brought to within a low voltage (see
Specifi cations) with respect to –Vin.
Off is grounded or brought to within a low voltage (see Specifi cations) with
respect to –Vin. The device is off (disabled) when the On/Off is left open or is
pulled high to approximately +15V with respect to –Vin.
signal current when brought low and withstand appropriate voltage when
brought high. Be aware too that there is a fi nite time in milliseconds (see
Specifi cations) between the time of On/Off Control activation and stable,
regulated output. This time will vary slightly with output load type and current
and input conditions.
Positive: Standard models are enabled when the On/Off pin is left open or
Negative: Optional negative-polarity devices are on (enabled) when the On/
Dynamic control of the On/Off function should be able to sink appropriate
www.murata-ps.com
you carefully observe the voltage levels, the preferred circuit is either an open
drain/open collector transistor, a switch or a relay (which can thereupon be
controlled by logic) returned to negative Vin.
power voltage. Otherwise the converter may be permanently damaged.
Output Capacitive Load
These converters do not require external capacitance added to achieve rated
specifi cations. Users should only consider adding capacitance to reduce switch-
ing noise and/or to handle spike current step loads. Install only enough capaci-
tance to achieve noise objectives. Excess external capacitance may cause
regulation problems, slower transient response and possible instability. Proper
wiring of the Sense inputs will improve these factors under capacitive load.
capacitor installed immediately adjacent to the converter. Any extended output
wiring or smaller wire gauge or less ground plane may tolerate somewhat higher
capacitance. Also, capacitors with higher ESR may use a larger capacitance.
There are several CAUTIONs for the On/Off Control:
CAUTION: While it is possible to control the On/Off with external logic if
CAUTION: Do not apply voltages to the On/Off pin when there is no input
The maximum rated output capacitance and ESR specifi cation is given for a
Technical enquiries email: sales@murata-ps.com, tel:
Isolated, High-Density, Eighth-Brick
100W DC/DC Converters
MDC_UCE.A18 Page 11 of 16
UCE Series
+1 508 339 3000

Related parts for MDC_UCE