MDC_UEI-50-60W MURATA [Murata Manufacturing Co., Ltd.], MDC_UEI-50-60W Datasheet - Page 5

no-image

MDC_UEI-50-60W

Manufacturer Part Number
MDC_UEI-50-60W
Description
50-60W Isolated Wide-Range DC/DC Converters
Manufacturer
MURATA [Murata Manufacturing Co., Ltd.]
Datasheet
Specifi cation Notes:
(1) All models are tested and specifi ed with external 1||10 μF output capacitors and a 22 μF external
input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate
our test equipment and may not be required to achieve specifi ed performance in your applications. All
models are stable and regulate within spec under no-load conditions.
All specifi cations are typical unless noted. General conditions for Specifi cations are +25 deg.C,
Vin=nominal, Vout=nominal, full load. Adequate airfl ow must be supplied for extended testing under
power.
(2) Input Back Ripple Current is tested and specifi ed over a 5 Hz to 20 MHz bandwidth. Input fi ltering
is Cin=33 μF, 100V, Cbus=220 μF, 100V, Lbus=12 μH.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage.
At higher temperatures and/or lower airfl ow, the DC/DC converter will tolerate brief full current
outputs if the total RMS current over time does not exceed the Derating curve. All Derating curves
are presented at sea level altitude. Be aware of reduced power dissipation with increasing density
altitude.
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3,
ground fi xed conditions, Tpcboard=+25 deg.C, full load, natural air convection.
(5) The On/Off Control is normally selected by a switch or an open collector or open drain transistor.
But it may also be driven with external logic or by applying appropriate external voltages which are
referenced to Input Common and do not exceed the On/Off voltage specifi cations.
(6) Output current limiting begins when the output voltage degrades approximately 2% from the
selected setting.
(7) The outputs are not intended to sink appreciable reverse current.
(8) Output noise may be further reduced by adding an external fi lter. Low voltage logic circuits may
have a small voltage margin between logic ZERO and logic ONE, requiring noise suppression. Use only
ISOLATION CHARACTERISTICS
MISCELLANEOUS CHARACTERISTICS
UEI-3.3/15-Q12
UEI-3.3/18-Q48
UEI-5/10-Q12
UEI-5/12-Q48
UEI-12/4.2-Q12
UEI-12/5-Q48
UEI-15/3.3-Q12
UEI-15/4-Q48
UEI-3.3/18-Q48
UEI-5/10-Q12
UEI-5/12-Q48
UEI-12/4.2-Q12
UEI-12/5-Q48
UEI-15/3.3-Q12
UEI-15/4-Q48
UEI-3.3/15-Q12
Model Family
Model Family
Limit Inception
Output Current
after warmup
98% of V
Input to
Output.
15.5
6.1
5.3
5.8
20
23
14
2000
2250
2000
2250
2000
2250
2000
2250
A
6
VDC
Min
OUT
,
Protection
Resistance
Method
limiting,
Isolation
Current
Output
Circuit
hiccup
restart
Short
auto
Min
10
10
10
10
10
10
10
10
www.murata-ps.com
Capacitance Isolation Safety
Current
Output
Circuit
Short
Isolation
0.06
TBD
0.5
0.5
A
1000
pF
(output shorted
Short Circuit
to ground)
Continuous
Duration
Output
insulation
Rating
Basic
Pre-biased
V
Monotonic
(external
OUT
setup
< V
as much output fi ltering as needed to achieve your noise requirements. Excessive output capacitance
can retard transient response or possibly cause instability. Low ESR ceramic capacitors may degrade
dynamic performance. Be sure to thoroughly test your system under full load with all components
installed.
(9) All models are fully operational and meet published specifi cations, including “cold start” at –40°C.
At full power, the package temperature of all on-board components must not exceed +128°C.
(10) Regulation specifi cations describe the deviation as the line input voltage or output load current is
varied from a nominal midpoint value to either extreme.
(11) The output overvoltage protection is automatic recovery. The overvoltage may occur either from
internal failure or from an external forcing voltage as in a shared power system.
(12) Output current limit and short circuit protection is non-latching. When the overcurrent fault is
removed, the converter will immediately recover. After an output overcurrent or short circuit, “hiccup”
operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcur-
rent condition still exists, the restart current will be removed and then tried again. This short current
pulse prevents overheating and damaging the converter. Once the fault is removed, the converter
immediately resumes normal operation.
(13) Do not exceed maximum power specifi cations when adjusting the output trim.
(14) At zero output current, the output may contain low frequency components which exceed the
ripple specifi cation. The output may be operated indefi nitely with no load.
(15) If reverse polarity is accidentally applied to the input, to ensure reverse input protection with full
output load, always connect an external input fuse in series with the +Vin input. Use approximately
twice the full input current rating with nominal input voltage.
CAUTION: This product is not internally fused. To comply with safety agency certifi cations and to
avoid injury to personnel or equipment, the user must connect an external fast-blow fuse to the input
terminals. See fuse information.
SET
)
DYNAMIC CHARACTERISTICS
UEI-3.3/15-Q12
UEI-3.3/18-Q48
UEI-5/10-Q12
UEI-5/12-Q48
UEI-12/4.2-Q12
UEI-12/5-Q48
UEI-15/3.3-Q12
UEI-15/4-Q48
Calculated
2,000,000
Model Family
MTBF
Hours
50-60W Isolated Wide-Range DC/DC Converters
Operating Temperature
Technical enquiries email: sales@murata-ps.com, tel:
–40 to +85ºC;
with Derating
Dynamic Load
(see Notes)
100 to 2% V
180 to 2% V
100 to 2% V
200 to 1% V
400 to 1% V
150 to 1% V
(50-75-50%
load step)
Range
Response
μsec
TBD
OUT
OUT
OUT
OUT
OUT
OUT
MDC_UEI Series 50-60W.B24 Page 5 of 12
V
regulated
IN
(Max.)
mSec
to V
50
temperature
–55 to 125ºC
Storage
Start-up Time
OUT
range
ºC
regulated (Max.)
Remote On/Off
UEI Series
to V
mSec
protection/
shutdown
50
Thermal
OUT
115
ºC
+1 508 339 3000
condensing
Frequency
Switching
Humidity,
To +85ºC/
Relative
non-
85%
KHz
275
280
275
250
265
TBD
ºC

Related parts for MDC_UEI-50-60W