MPG-120S MPD [MicroPower Direct, LLC], MPG-120S Datasheet

no-image

MPG-120S

Manufacturer Part Number
MPG-120S
Description
Single Output, 120W Green, Open Frame AC/DC Power Supplies
Manufacturer
MPD [MicroPower Direct, LLC]
Datasheet
MPG-120S
Key Features:
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Single Output, 120W
Green, Open Frame
AC/DC Power Supplies
120W Output Power
150W With Only 7 CFM
Universal 85-264 AC Input
EN 60950 Approved (UL)
Meets ErP Directive
Compact 3 x 5 Inch Size
PFC Meets EN 61000-3
Optional +5V SB Output
>400 kHour MTBF
Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Parameter
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coeffi cient
Over Voltage Protection
Short Circuit Protection
Input
Parameter
Input Voltage Range
Input Frequency
Input Filter
Input Current
Inrush Current
Power Factor Correction
Leakage Current
No Load Power Consumption
Output
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI Characteristics
Parameter
Voltage Dips, See Note 6
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Reliability Specifi cations
Parameter
MTBF
Safety Standards
Radiated Emissions, See Note 5
Conducted Emissions , See Note 5
ESD
RS
EFT
Surge
CS
PFMF
www.micropowerdirect.com
Series
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
Conditions
Conditions
Conditions
Conditions
Standard
RH, Non-condensing
Cold Start, 115 VAC
Cold Start, 230 VAC
Free Air Convection (See Derating Curve)
Meets EN 55022 Class B; FCC Class B
EN 61000-4-11
Input to Output
Meets EN 61000-3-2/3 Class A
5.00 x 3.00 x 1.35 Inches (127.00 x 76.20 x 34.2 mm)
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
See Model Selection Guide
See Model Selection Guide
Continuous (Autorecovery)
See Note 1
See Note 2
See Note 3
See Note 4
EN 55022
EN 55022
UL 60950, EN 60950
Universal
500 VDC
115 VAC
230 VAC
Ambient
Fixed
Criteria A/B; Volt. Dips 60%, 5 Cycles
Criteria C; Volt. Inter, >95%, 250 Cycles
Criteria A; Volt. Dips >95%, 0.5 Cycle
3,000
Criteria A; L-N: ±1kV, L/N-PE: ±2kV
Criteria A; Volt. Dips 30%, 25 Cycles
Criteria A; ±8 kV Air/±6 kV Contact
Min.
Min.
Min.
Min.
Min.
Min.
110
400
-20
-40
85
47
Criteria A; ±2 kV Line & PE
±0.05
2,200
Criteria A; 10 Vrms
Criteria A; 10A/ms
Typ.
Typ.
±1.0
±1.0
±1.0
±1.0
Typ.
Typ.
Typ.
Typ.
140
100
Criteria A; 10V/m
+25
20
40
65
Class B
Class B
Max.
Max.
Max.
Max.
Max.
Max.
30.0
60.0
0.25
264
373
+70
+85
9.87 Oz (0.280 kg)
0.5
63
95
kHours
mSec
Units
Units
%/°C
Units
Units
Units
Units
VDC
A Pk
VAC
VAC
kHz
M
mA
Hz
pF
°C
°C
%
%
%
%
%
%
W

Related parts for MPG-120S

MPG-120S Summary of contents

Page 1

... MPG-120S Single Output, 120W Green, Open Frame AC/DC Power Supplies Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Key Features: Input • 120W Output Power Parameter • ...

Page 2

... MPG-120S-12SB 2.50 1.25 MPG-120S-24 2.50 1.25 MPG-120S-24SB 2.50 1.25 MPG-120S-48 2.50 1.25 MPG-120S-48SB 2.50 1.25 Notes: 1. Output voltage tolerance is measured at 110 VAC input and 60% load. 2. Line regulation is measured at a 115 VAC input with the rated load. The line is varied ±10%. 3. Load regulation is specifi ed for a load change of 60% ±40% (of full load). ...