T20-A230XF EPCOS [EPCOS], T20-A230XF Datasheet - Page 3

no-image

T20-A230XF

Manufacturer Part Number
T20-A230XF
Description
SURGE ARRESTER 2-electrode arrester
Manufacturer
EPCOS [EPCOS]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
T20-A230XF
Manufacturer:
EPCOS
Quantity:
5 483
Part Number:
T20-A230XFP
Manufacturer:
EPCOS
Quantity:
5 471
1)
2)
3)
4)
5)
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
The arrester failsafe mechanism contains a solder pellet with a melting
temperature between 193 and 203 °C.
Dimensional drawing
Cautions and warnings
KB AB E / KB AB PM
Please read Cautions and warnings and
Important notes at the end of this document.
Surge arrester
3-electrode arrester
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
Test according to ITU-T Rec. K.12
Tip or ring electrode to center electrode
Total current through center electrode, half value through
tip respectively ring electrode.
The short-circuit spring does not trigger until 180 °C is reached depending on the material. Care
must be taken to limit the thermal radiation onto adjacent parts to safe values.
Surge arresters must not be operated directly in power supply networks.
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
Damaged surge arresters must not be re-used.
Page 3 of 4
Not to scale
Dimensions in mm
Non controlled document
B88069X8720B502
Issue 04 / 2007-10-18
T20-A230XF