g5v-2-h1 Omron Corporation, g5v-2-h1 Datasheet - Page 3

no-image

g5v-2-h1

Manufacturer Part Number
g5v-2-h1
Description
Miniature Relay For Signal Circuits
Manufacturer
Omron Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5V-2-H1
Manufacturer:
OMRON
Quantity:
20 000
Part Number:
G5V-2-H1
Manufacturer:
PAN
Quantity:
5 510
Part Number:
G5V-2-H1
Manufacturer:
COPAL
Quantity:
5 510
Part Number:
g5v-2-h1 12VDC
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
g5v-2-h1 48VDC
Quantity:
12 000
Company:
Part Number:
g5v-2-h1-12V
Quantity:
15 000
Part Number:
g5v-2-h1-12VDC
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Company:
Part Number:
g5v-2-h1-12VDC
Quantity:
5 655
Company:
Part Number:
g5v-2-h1-24V
Quantity:
5 655
Part Number:
g5v-2-h1-24VDC
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Company:
Part Number:
g5v-2-h1-24VDC
Quantity:
5 655
■ Characteristics
Note: Data shown are of initial value.
■ Characteristic Data
Contact resistance
Operate time
Release time
Bounce time
Operating frequency
Insulation resistance
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Maximum Switching Capacity
Rated operating voltage (V)
Operate
Release
Mechanical
Electrical
Mechanical durability 10 to 55 Hz, 1.50 mm (0.59 in) double amplitude
Malfunction durability
Mechanical durability 1,000 m/s
Malfunction durability 200 m/s
Operating/storage
Mechanical
Electrical
Electrical Service Life
50 mΩ max. G5V-2, G5V-2-H, 100 mΩ max. G5V-2-H1
7 ms max. (mean value: approx. 3.5 ms)
3 ms max. (mean value: approx. 0.8 ms)
Mean value: approx. 0.5 ms
Mean value: approx. 3.5 ms
36,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same poles
(500 VAC, 50/60 Hz for 1 minute between contacts of same poles for ultra-sensitive type)
1,500 V 10 X 160 µs (conforms to part 68 of FCC rules)
-25° to 70°C (-13° to 158°F)
35% to 85% RH
15 million operations min. (at operating frequency of 36,000 operations/hour)
See “Characteristic Data”
6 g (0.21 oz)
Rated operating current (A)
2
(approx. 20 G), 100 m/s
2
(approx. 100 G)
2
(approx. 10 G) for ultra-sensitive type
Low Signal Relay
Ambient Temperature vs. Maximum Voltage
— 48 VDC coil voltage (standard type)
— All other types and voltages
Rated operating current (A)
G5V-2
3

Related parts for g5v-2-h1