nph15s C&D Technologies., nph15s Datasheet
nph15s
Available stocks
Related parts for nph15s
nph15s Summary of contents
Page 1
... Internal over temperature protection n Uses no electrolytic capacitors n DESCRIPTION The NPH15S series of DC/DC converters combines ease of application with versatility. The pin pattern is based on the popular industry standard, but two additional pins may optionally be fitted to provide a variety of features not commonly found on units of this type. High efficiency enables full rating to ...
Page 2
... Absolute Max. internal temperature Relative humidity Non condensing 85ºC Thermal protection Operates at case temperature THERMAL CHARACTERISTICS UL 1950 recognition: Max. permissable loads for a given ambient temperature for any NPH15S model. Temperature (º Max. power rating with case temperature maintained by external means (e.g. forced air cooling). ...
Page 3
... NPH15S When the output voltage is trimmed up, output current must be derated so that the maximum output power is not exceeded. Example to decrease output voltage of NPH15S4805EiC by 0.1V: SET VOLTAGE The output voltage of all units is set to 100mV above nominal, to offset resistive losses and thus assist with worst case error calculations. For the EiC versions, this allowance can be altered with a single fixed resistor, connected from the trimming pin to one of the output pins ...
Page 4
... A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The NPH15S series has been recognized by Underwriters Laboratory, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier ...
Page 5
... MPS 18R104C MPS 18R472C 100µH 1.2A 4.7µH 5.35A MPS 18R104C MPS 18R103C 100µH 1.2A 10µH 3.45A MPS 18R104C MPS 18R333C 100µH 1.2A 33µH 2.00A MPS 18R104C MPS 18R333C 100µH 1.2A 33µH 2.00A +44 (0)1908 615232 KDC_NPH15SC.F02 Page ...
Page 6
... EMC FILTERING AND SPECTRA (continued) NPH15S2403 NPH15S2412 NPH15S4803 www.murata-ps.com NPH15S Series Isolated 15W Single Output DC/DC Converters NPH15S2405 NPH15S2415 NPH15S4805 Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NPH15SC.F02 Page ...
Page 7
... EMC FILTERING AND SPECTRA (continued) NPH15S4812 www.murata-ps.com NPH15S Series Isolated 15W Single Output DC/DC Converters NPH15S4815 Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NPH15SC.F02 Page ...
Page 8
... Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Technical enquiries - email: mk@murata-ps.com, tel: KDC_NPH15SC.F02 Page Tube Quantity: 15 +44 (0)1908 615232 ...