f75334 Feature Integration Technology Inc., f75334 Datasheet - Page 49

no-image

f75334

Manufacturer Part Number
f75334
Description
Performance Controller
Manufacturer
Feature Integration Technology Inc.
Datasheet
6-0 BOUND1TMP3
6-0 BOUND2TMP3
6-0 BOUND3TMP3
6-0 BOUND4TMP3
Bit
Bit
Bit
Bit
8.2.57 VT3 BOUNDARY 1 TEMPERATURE – Index C6h
8.2.58 VT3 BOUNDARY 2 TEMPERATURE – Index C7
8.2.59 VT3 BOUNDARY 3 TEMPERATURE – Index C8h
8.2.60 VT3 BOUNDARY 4 TEMPERATURE – Index C9
7
7
7
7
C4h
C5h
Reserved
Reserved
Reserved
Reserved
Name
Name
Name
Name
R/W
R/W
8’h03
R/W Default
R/W
R/W Default
R/W
R/W Default
R/W
R/W Default
R/W
8’hff
RO
RO
RO
RO
(60
(50
(40
(30
3Ch
1Eh
28h
32
FAN3 expect speed count value (LSB) or expect PWM duty , in auto fan mode
this register is auto updated by hardware and read only.
Duty mode(CR96 bit4=1):
The Value programming in this byte is duty value. In auto fan mode(CR96
bit5
Ex:
FAN3 full speed count reading (MSB). At the moment of reading this register,
the LSB will be latched. This will prevent from data updating when reading. To
read the fan count correctly, read MSB first and followed read the LSB.
FAN3 full speed count reading (LSB).
0
0
0
0
o
o
o
o
C)
C)
C)
C)
255
Return 0 when read.
The 1
When VT3 temperature is exceed this boundary, FAN3 expect value will
load from segment 1 register (index CA)h.
When VT3 temperature is below this boundary – hysteresis, FAN3 expect
value will load from segment 2 register (index CAh).
Return 0 when read.
The 2
When VT3 temperature is exceed this boundary, FAN3 expect value will
load from segment 2 register (index CB)h.
When VT3 temperature is below this boundary – hysteresis, FAN3 expect
value will load from segment 3 register (index CBh).
Return 0 when read.
The 3
When VT3 temperature is exceed this boundary, FAN3 expect value will
load from segment 3 register (index CC)h.
When VT3 temperature is below this boundary – hysteresis, FAN3 expect
value will load from segment 4 register (index CCh).
Return 0 when read.
The 4
When VT3 temperature is exceed this boundary, FAN3 expect value will
load from segment 4 register (index CDh).
When VT3 temperature is below this boundary – hysteresis, FAN3 expect
value will load from segment 5 register (index CDh).
0) this register is updated by hardware.
5
5*100/255 %
st
st
st
st
100%
BOUNDARY temperature for VT3 in temperature mode.
BOUNDARY temperature for VT3 in temperature mode.
BOUNDARY temperature for VT3 in temperature mode.
BOUNDARY temperature for VT3 in temperature mode.
42
Description
Description
Description
Description
F75334
July, 2007
V0.25P

Related parts for f75334