DMS-05V MURATA [Murata Manufacturing Co., Ltd.], DMS-05V Datasheet - Page 2

no-image

DMS-05V

Manufacturer Part Number
DMS-05V
Description
Manufacturer
MURATA [Murata Manufacturing Co., Ltd.]
Datasheet
Performance/Functional Specifications
Typical at T
Inputs
Full Scale Input Range
Input Impedence
Overvoltage Protection
Performance
Sampling Rate
Accuracy (1 minute warm-up):
Temperature Drift (0 to +60°C)
Power Supply Requirements
DMS-20PC-0/5-5RS (@90mA max.)
DMS-20PC-0/5-5GS (@120mA max.) +4.75
DMS-20PC-0/5-5RL (@15mA max.)
DMS-20PC-0/5-5RH (@90mA max.)
DMS-20PC-0/5-24RS (@15mA max.)
Display
Display Type and Size
Polarity Indication
Overrange Indication
Physical/Environmental
Operating Temperature
Storage Temperature
Humidity (non-condensing)
Case Material
Weight
Ordering Information
The DMS-20PC-0/5 can also be used in most 0-10V applications. See the section
on 0-10V inputs for more information. See Note 3 on Table 1.
INPUT LO (TB1 "–LO") is internally connected to the power return (TB2 "–V").
Overvoltage specifications apply to the INPUT HI (TB1 "+HI") connection.
DMS-20PC-0/5-5RS-C +5V supply, standard-intensity red LED's
DMS-20PC-0/5-5GS-C +5V supply, standard-intensity green LED's
DMS-20PC-0/5-5BS-C +5V supply, bright blue LED's
DMS-20PC-0/5-5RL-C +5V supply, low-power red LED's
DMS-20PC-0/5-5RH-C +5V supply, high-intensity red LED's
DMS-20PC-0/5-24RL-C +5V to +40V supply, low-power red LED's
DMS-PS1-CM-C
DMS-PS4-CM-C
DMS-PS7-CM-C
DMS-20-CP
Note: A DMS-BZL4 bezel assembly with a sealing gasket is supplied with each meter.
A
= +25°C, unless otherwise noted.
+5V/1.0A AC/DC power supply module
+24V/0.45A AC/DC power supply module
+24V/0.7A AC/DC power supply module
Panel cutout punch
+4.75
+4.75
+4.75
+4.75
Min.
–20
100
4.9
0
0
3½ digit, 0.37"/9.4mm high LED
"–1_ _ _ " for negative inputs
"1_ _ _ " for positive inputs
2.5 reading per second
0.6 ounces (17 grams)
±0.05%FS ±1 Count
"–" for negative V
±0.15
+5.00
+5.00
+5.00
+5.00
Typ.
5.0
Polycarbonate
www.murata-ps.com
+5.25
+5.25
+5.25
+5.25
+40.0
Max.
±0.3
140
±40
+60
+75
5.1
95
IN
Volts
Volts
Volts
Volts
Volts
Cnts/°C
Units
Volts
Volts
°C
°C
%
1. Input Configuration: The DMS-20PC-0/5 has its input low terminal
2. Panel Mounting: In most standard through-the-panel installations,
TECHNICAL NOTES
OPERATING AND SETUP INSTRUCTIONS
As shipped, the DMS-20PC-0/5 is factory calibrated to read "000" for
a 0.0V input and "1999" for a 5.0V input. The following worst-case
procedure assumes the DMS-20PC-0/5 is completely mis-adjusted, i.e.,
both potentiometers and the DIP switches are randomly set.
1. Set R7 (full scale span/gain adjust) and R3 (zero/offset adjust) fully
2. Select DIP switch setting #1 in Table 1.
3. Apply a precision 0.0V input and adjust R3 until the meter's display
4. Apply a precision 5.0V input and adjust R7 until the meter's display
5. Select the appropriate decimal point by setting SW6, SW7 or SW8 to
(TB1 "LO") internally connected to the power supply ground terminal
(TB2 "–V"). This connection effectively places the meter's input in a
single-ended configuration. In some applications, single-ended inputs
can cause ground-loop induced errors (the meter's display becomes
unstable or bounces). This occurs because the LED drive currents
flow through both the –V terminal and the signal LO terminal.
If suspected ground-loop errors are encountered, and the input signal
LO terminal is externally connected to –V somewhere else in the
system, try removing the connection to TB1 "LO". Inputs which have
no ground-return connection to –V (commonly referred to as "floating
inputs") must have their most negative potential tied to TB1 "LO".
Please consult DATEL for more information.
Applications which require electrical isolation between the input
signal source and the system power supply must use a separate
transformer-isolated supply to power the meter.
the DMS-20PC-0/5 must be secured to the panel with DMS-BZL4
bezel assemblies (see the Mechanical Specifications section for more
information).
clockwise, roughly 22 turns, and place SW1-SW8 to OFF (down
position).
reads "000".
reads "1999". Repeat steps 3 and 4 to make sure the adjustments
do not affect one another.
ON (DP1, DP2 or DP3 respectively).
NOTE: The "000" to "1999" display readings referred to in the
instructions above are for illustrative purposes only. If other display
readings such as "000" to "1200" are desired, refer to the DIP-
Switch Settings Tables for SW1-SW4 settings. (SW5 is reserved for
future use, it has no affect on display operation.) The initial setting
of R3 and R7 fully clockwise is recommended in the adjustment
procedure for all the following examples.
Technical enquiries email: sales@murata-ps.com, tel:
DMS-20PC-0/5 Series
0-5V and 0-10V Input 3½ Digit, LED
Display Process Control Monitors
MPM_DMS20pc_5V.B04 Page 2 of 4
+1 508 339 3000

Related parts for DMS-05V