mfl283r3s Interpoint Corp., mfl283r3s Datasheet

no-image

mfl283r3s

Manufacturer Part Number
mfl283r3s
Description
Mfl Single And Dual Dc/dc Converters
Manufacturer
Interpoint Corp.
Datasheet
DESCRIPTION
The MFL Series™ 28-volt DC/DC converters are rated up to 65
watts of output power over a –55°C to +125°C temperature range
with a 28 VDC nominal input. On dual output models up to 70% of
the rated output power can be drawn from either the positive or
negative output. Current sharing allows the units to be paralleled for
total power of up to 148 watts. The welded, hermetically sealed
package is only 3.005 x 1.505 x 0.400 inches, giving the series an
overall power density of up to 43 watts per cubic inch.
D
The MFL Series converters are switching regulators that use a
quasi-square wave, single ended forward converter design with a
constant switching frequency of 600 kHz.
Isolation between input and output circuits is provided with a trans-
former in the forward path and a wide bandwidth magnetic coupling
in the feedback control loop. The MFL uses a unique dual loop feed-
back technique that controls output current with an inner feedback
loop and an output voltage with a cascaded voltage mode feedback
loop.
The additional secondary current mode feedback loop improves
transient response in a manner similar to primary current mode
control and allows for ease of paralleling, but without the cost and
complexity.
The constant frequency, pulse-width modulated converters use a
quasi-square wave single-ended forward design. Tight load regula-
tion is achieved through a wide-bandwidth magnetic feedback
circuit. The output on single MFL models can be trimmed (see
Figure 1 for voltage changes with different resistor values).
Crane Aerospace & Electronics
Electronics Group (Interpoint Brand)
PO Box 97005 • Redmond WA 98073-9705
425.882.3100 • electronics@craneae.com
www.craneae.com
F
• –55° to +125°C operation
• 16 to 40 VDC input
• Fully Isolated
• Magnetic feedback
• Fixed frequency, 600 kHz typical
• Topology – Single Ended Forward
• 50 V for up to 120 ms transient protection
• Inhibit (input & output side)
• Sync function (in and out)
• Output trim on single output models
• Indefinite short circuit protection
• Remote sense on single output models
• Up to 87% efficiency / 43 W/in
• Parallelable up to 148 watts
ESIGN
EATURES
F
EATURES
MFL Single and Dual DC/DC Converters
3
28 VOLT INPUT – 65 WATT
Rev D - 20060601
Page 1 of 13
I
The MFL Series converters have two TTL compatible inhibit termi-
nals (INH1 and INH2) that can be used to disable power conversion,
resulting in a very low quiescent input current and no generation of
switching noise. An open collector TTL compatible low (<0.8 volts)
is required to inhibit the converter between INH1 (pin 4) and Input
Common (pin 2). An open collector TTL compatible low (<0.5 volts)
is required to inhibit the converter between INH2 (pin 12) and Output
Common (pin 8). The application of intermediate voltages to these
pins (1.5 to 10.5 volts) should be avoided.
S
Converters may be synced to an external clock (525 to 675 kHz) or
to one another by using the sync in or out pins. The nominal free-
run switching frequency is 600 kHz.
C
Multiple MFL converters may be used in parallel to drive a common
load (see Figure 2). In this mode of operation the load current is
shared by two or three MFL converters. In current sharing mode,
one MFL converter is designated as a master. The SLAVE pin (pin
11) of the master is left unconnected and the MSTR/INH2 pin (pin
12) of the master is connected to the SLAVE pin (pin 11) of the slave
units. The units designated as slaves have the MSTR/INH2 pin (pin
12) connected to the SNS RTN pin (pin 9). Figure 2 shows the
typical setup for two or three units in parallel. Note that synchro-
nizing the units together (though shown in the figure) is not required
for current sharing operation. A second slave unit may be placed in
parallel with a master and slave; this requires the TRI pin (pin 3) of
the master unit to be connected to the SNS RTN pin (pin 9).
When paralleled, 76% of the total combined power ratings of the
MFL converters are available at the load. Overload and short circuit
performance are not adversely affected during parallel operation.
NHIBIT
YNC
URRENT AND
Crane Aerospace & Electronics Power Solutions
P
ARALLEL
O
SINGLE
available upon request,
including 2 V, 8 V and
Other output voltages
PERATION
3.3
12
15
28
5
VDC O
MODELS
54 V single.
UTPUT
DUAL
±12
±15
±5

Related parts for mfl283r3s

mfl283r3s Summary of contents

Page 1

MFL Single and Dual DC/DC Converters F EATURES • –55° to +125°C operation • VDC input • Fully Isolated • Magnetic feedback • Fixed frequency, 600 kHz typical • Topology – Single Ended Forward • ...

Page 2

... Derate Output Power/Current • Linearly from 100% at 125° 135°C • MFL283R3S: linearly from 100% at 100°C to 80% at 125°C and 135°C Output Voltage Temperature Coefficient • 100 ppm/°C typical Input to Output Capacitance • ...

Page 3

MFL Single and Dual DC/DC Converters PIN OUT Pin Single Output MFL2828S 1 Positive Input Positive Input 2 Input Common Input Common 3 Triple (TRI) Triple (TRI) 4 Inhibit 1 (INH1) Inhibit 1 (INH1) 5 Sync Out Sync Out 6 ...

Page 4

MFL Single and Dual DC/DC Converters SINGLE OUTPUT MODELS CONNECTION DIAGRAMS - SENSE AND PARALLEL + 28V – Inhibit Sync In + 28V – Inhibit Sync In + 28V – Inhibit Sync In www.craneae.com 28 VOLT INPUT – 65 WATT ...

Page 5

... H, QML) Page Rev D - 20060601 SMD NUMBERS S M MFL S TANDARD ICROCIRCUIT D (SMD) S RAWING IMILAR IN PROCESS MFL283R3S 5962-9316301HXC MFL2805S/883 5962-9316201HXC MFL2812S/883 5962-9316101HXC MFL2815S/883 IN PROCESS MFL2828S/883 5962-9319101HXC MFL2805D/883 5962-9319201HXC MFL2812D/883 5962-9319301HXC MFL2815D/883 For exact specifications for an SMD product, refer to the SMD drawing ...

Page 6

... OUT Notes 1. Guaranteed by design, not tested. 2. MFL283R3S current and power maximum are at 25°C only. 3. Unit will shut down above approximately 45V but will be undamaged and will restart when voltage drops into normal range. 4. Recovery time is measured from application of the transient to point at which Vout is within 1% of final value ...

Page 7

MFL Single and Dual DC/DC Converters Electrical Characteristics: –55°C to +125° C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. SINGLE OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT OUTPUT POWER OUTPUT RIPPLE VOLTAGE ...

Page 8

MFL Single and Dual DC/DC Converters Electrical Characteristics: –55°C to +125° C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. DUAL OUTPUT MODELS PARAMETER CONDITIONS OUTPUT VOLTAGE 2 OUTPUT CURRENT EACH OUTPUT ...

Page 9

MFL Single and Dual DC/DC Converters Typical Performance Curves: 25° VDC Vin, 100% load, free run, unless otherwise specified 16V 80 28V 75 40V Output (Watts) MFL2805S ...

Page 10

MFL Single and Dual DC/DC Converters Typical Performance Curves: 25° VDC Vin, 100% load, free run, unless otherwise specified. 50% to 100% –Pout = 32.5W 100% to 50% 1ms/div MFL2815D Step Load Response F 13 IGURE 16 ...

Page 11

... Please refer to the numerical dimensions for accuracy. All information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. Copyright © 1999-2006 Interpoint Corp. All rights reserved. www.craneae.com 28 VOLT INPUT – 65 WATT ...

Page 12

MFL Single and Dual DC/DC Converters 883 QML P LASS E LEMENT T EST ( COMPONENT LEVEL Element Electrical (probe) Element Visual Internal Visual Final Electrical Wire Bond Evaluation SLAM™/C-SAM: Input Capacitors only (Add’l test, not req. by ...

Page 13

MFL Single and Dual DC/DC Converters 883, C LASS TEST Pre-cap Inspection Method 2017, 2032 Temperature Cycle (10 times) Method 1010, Cond. C, -65°C to 150°C, ambient Method 1010, Cond. B, -55°C to 125°C, ambient Constant Acceleration Method 2001, 3000 ...

Related keywords