Removing the Contact Block
First unlock the operator button.
Grab the yellow bayonet ring ➀
and pull back the bayonet ring
until the latch pin clicks ➁, then
turn the contact block counter-
clockwise and pull out ➂.
Notes for removing the contact block
1. Do not attempt to remove the contact block while the oper-
2. When the contact block is removed, the monitor contact
3. While removing the contact block, do not use excessive
4. An LED lamp is built into the contact block for illuminated
Panel Mounting
Remove the locking ring from
the operator and check that
the rubber gasket is in place.
Insert the operator from panel
front into the panel hole. Face
the side without thread on the
operator with TOP marking
upward, and tighten the lock-
ing ring using ring wrench
XN9Z-T1 or TWST-T1 to a torque of 2.5 N·m maximum.
When using a nameplate
When using a nameplate HNAV- , break
the projection from the nameplate using
pliers.
Installing the Contact Block
First unlock the operator button.
Align the small ▼ marking on
the edge of the operator with the
small ▲ marking on the yellow
bayonet ring. Hold the contact
block, not the bayonet ring.
Press the contact block onto the
operator and turn the contact
block clockwise until the bayo-
net ring clicks.
Notes for installing the contact block
1. Do not attempt to install the contact block when the opera-
2. Make sure that the bayonet ring is in the locked position.
ator is latched, otherwise the switch may be damaged.
(NO contact) is closed.
force, otherwise the switch may be damaged.
pushbuttons. When removing the contact block, pull the
contact block straight to prevent damage to the LED lamp.
If excessive force is used, the LED lamp may be damaged
and fail to light.
tor is latched, otherwise the switch may be damaged.
Operating Instructions
Anti-rotation
Projection
Rubber Gasket
➂ Turn counterclockwise
▼ Marking
➀ Grab
➀ Push
➁ Pull
Bayonet Ring (yellow)
XN
Projection
Locking Ring
▲ Marking
➁ Turn clockwise
Operator without
thread
TOP Marking
Latch
TOP Marking
Series
➀ Grab
Emergency Stop Switches
Installing & Removing Terminal Covers
• XW9Z-VL2M
To install the terminal cover,
align the TOP marking on
the terminal cover with the
TOP marking on the contact
block. Place the two projec-
tions on the bottom side of
the contact block into the
slots in the terminal cover.
Press the terminal cover
toward the contact block.
To remove the terminal cover,
pull out the two latches on the
top side of the terminal cover.
Do not exert excessive force to
the latches, otherwise the
latches may break.
IP20 Fingersafe Terminal
Cover XW9Z-VL2MF
To install the IP20 fingersafe terminal
cover, align the TOP marking on the
cover with the TOP marking on the
contact block, and press the cover
toward the contact block.
Notes:
1. Once installed, the XW9Z-VL2MF cannot
2. With the XW9Z-VL2MF installed, crimping terminals cannot be used.
3. The XW9Z-VL2MF cannot be installed after wiring.
4. Make sure that the XW9Z-VL2MF is securely installed. IP20 cannot
Notes for Operation
When using the XN emergency stop switches in safety-
related part of a control system, observe safety standards
and regulations of the relevant country or region. Also be
sure to perform a risk assessment before operation.
Wiring
Tighten the M3 terminal screws to a torque of 0.6 to 1.0
N·m.
Contact Bounce
When the button is reset by pulling or turning, the NC main
contacts will bounce. When pressing the button, the NO
monitor contacts will bounce.
When designing a control circuit, take the contact bounce
time into consideration (reference value: 20 ms).
LED Illuminated Switches
An LED lamp is built into the contact block and cannot be
replaced.
Handling
Do not expose the switch to excessive shocks and vibra-
tions, for example by operating the switch with tools. Other-
wise the switch may be deformed or damaged, causing
malfunction or operation failure.
be removed.
Use solid wires.
be achieved when installed loosely, and electric shocks may occur.
➀ Place the projections
Projections
on the contact block.
TOP Markings
TOP Marking
TOP Marking
TOP Marking
➁ Press the
(Pull)
TOP Marking
terminal cover
Slots
Projections
ø30
(Press)
11