thp-3-2411 Traco Power, thp-3-2411 Datasheet - Page 2

no-image

thp-3-2411

Manufacturer Part Number
thp-3-2411
Description
Dc/dc Converters
Manufacturer
Traco Power
Datasheet
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Input Specifications
Input current at no load / full load
Start-up voltage /
under voltage shut down
Recommanded input fuse (slow blow)
Surge voltage (1 sec. max.)
Input filter
Output Specifications
Voltage set accuracy
Voltage balance (dual output models)
Regulation
Ripple and noise (20 MHz Bandwidth)
Temperature coefficient
Current limitation
Short circuit protection
Capacitive load
Isolation / Safety
Isolation test voltage (flash tested 1 sec.)
I/O isolation voltage (50Hz, 60sec)
Leakage current
Isolation capacity
Isolation resistance
Safety standards
Safety approvals
– Input variation Vin min. to Vin max.
– Load variation 25 – 100 %:
– Input/Output
– Input/Output
12 VDC output models:
5 VDC output models: 1000 µF max.
Dual output models:
24 Vin models: 20 mA typ. / 160 mA typ.
48 Vin models: 10 mA typ. / 80 mA typ.
72 Vin models: 5 mA typ. / 35 mA typ.
24 Vin models: 8.5 VDC / 8.5 VDC (typ.)
48 Vin models: 15 VDC / 16 VDC (typ.)
72 Vin models: 30 VDC / 32 VDC (typ.)
24 Vin models: 1.0 A
48 Vin models: 0.5 A
72 Vin models: 0.3 A
24 Vin models: 50 V max.
48 Vin models: 100 V max.
72 Vin models: 180 V max.
EN 55022, level A (without external
± 1 %
± 2 % max.
0.5 % max.
1.0 % max.
150 mVpk-pk typ.
± 0.02 % / K typ.
> 120 % Iout max.
indefinite (automatic recovery)
6000 Vpk
4000 VACrms
2 µA (at 240VAC, 60Hz)
7 pF typ. (at 100KHz, 1V)
>1000 Mohm (at 500VDC)
IEC/EN 60950-1, UL 60950-1
CSA C22.2 No. 60950-1-03
IEC/EN 60601-1, EN 50124-1&2
UL 60601-1, CSA C22.2 No. 601-1
CB-report, CSA File No. 226037
470 µF max.
220 µF max. (each output)
DC/DC Converters
THP 3 Series
Page 2 of 3
3 Watt