AS1324 AMSCO [austriamicrosystems AG], AS1324 Datasheet - Page 9

no-image

AS1324

Manufacturer Part Number
AS1324
Description
1.5MHz, 600mA, DC/DC Step-Down Regulator
Manufacturer
AMSCO [austriamicrosystems AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AS1324-AD
Manufacturer:
AUSTRIAM
Quantity:
20 000
Part Number:
AS1324-BTTT-12
Manufacturer:
AUSTRIAMICROSY
Quantity:
20 000
Part Number:
AS1324-BTTT-15
Manufacturer:
AUSTRIAM
Quantity:
20 000
Part Number:
AS1324-BTTT-18
Manufacturer:
AUSTRIAMICROSY
Quantity:
20 000
Part Number:
AS1324-BTTT-AD
Manufacturer:
AUSTRIAMI
Quantity:
20 000
AS1324
Data Sheet - D e t a i l e d D e s c r i p t i o n
Powersave Operation
The AS1324 uses an automatic powersave mode where the peak inductor current (I
) is set to approximately 200mA
PK
while independent of the output load. In powersave mode, load current is supplied solely from the output capacitor. As
the output voltage drops, the error amplifier output rises above the powersave threshold signaling to switch into PWM
fixed frequency mode and turn the PMOS on. This process repeats at a rate determined by the load demand.
Each burst event can last from a few cycles at light loads to almost continuous cycling (with short sleep intervals) at
moderate loads. In between bursts, the power MOSFETs are turned off, as is any unneeded circuitry, reducing quies-
cent current to 30µA.
Short-Circuit Protection
In cases where the AS1324 output is shorted to ground, the oscillator frequency (f
) is reduced to 1/13 the nominal
OSC
frequency (
115kHz). This frequency reduction ensures that the inductor current has more time to decay, thus pre-
venting runaway conditions. f
will progressively increase to 1.5MHz when V
/V
> 0V.
OSC
FB
OUT
Shutdown
Connecting EN to GND or logic low places the AS1324 in shutdown mode and reduces the supply current to 0.1µA. In
shutdown the control circuitry and the internal NMOS and PMOS turn off and SW becomes high impedance discon-
necting the input from the output. The output capacitance and load current determine the voltage decay rate. For nor-
mal operation connect EN to V
or logic high.
IN
Note: Pin EN should not be left floating.
www.austriamicrosystems.com
Revision 1.03
9 - 20