NIPXI-2529 NI [National Instruments Corporation], NIPXI-2529 Datasheet

no-image

NIPXI-2529

Manufacturer Part Number
NIPXI-2529
Description
High-Density Multiconfiguration Matrix Modules
Manufacturer
NI [National Instruments Corporation]
Datasheet
High-Density Multiconfiguration
Matrix Modules
NI PXI-2529, NI PXIe-2529, NI SCXI-1129
Overview
The NI PXI-2529, PXIe-2529, and SCXI-1129 are high-density matrix relay
modules built for applications with high-channel counts. The modules are
two-wire matrices that are configurable with front mounting terminal blocks to
achieve many different matrix configurations. Table 1 provides a complete list of
possible configurations. Expanding the matrix channel count is as easy as adding
more modules. With the SCXI-1129, you can pass analog signals between two
or more switch modules via a high-voltage backplane (HVAB), matrix expansion
cables, or matrix expansion plugs. Using these connections, you can instantly
expand your matrix without external wiring. The NI 2529 modules are designed
to work well with both low- and high- voltage levels. They use relays with low
thermal offset to ensure accurate low-voltage measurements. These relays can
switch up to 150 V
Figure 1. The matrix expansion plug
simplifies expansion.
8 matrix configurations
Switch capacity
32,000-step scan list for
deterministic scanning
Fully software programmable
Effortless matrix expansion
Multiple-module synchronization
with hardware triggers
Electromechanical relays
Available in both PXI and PXI Express
versions for optimal slot placement
NI PXI-2529/PXIe-2529
NI SCXI-1129
150 VDC, 150 V
1 A switching/2 A carry
128-crosspoint matrix
4x32 and 8x16 2-wire
matrix configurations
256-crosspoint matrix
Six 2-wire matrix configurations
rms
rms
or 150 VDC.
CAT I
Matrix Operation
The NI 2529 modules are general-purpose,
two-wire matrices used to route differential
signals. Through software, you can control
the matrices to connect any row to any
column. One of the key advantages of
these modules is their adaptability to
your switching needs. You can configure
the SCXI-1129 in six different matrix
configurations and an NI 2529 in two
Operating Systems
Recommended Software
Other Compatible Software
Driver Software (included)
Windows XP/2000/NT
LabVIEW
LabWindows
Measurement Studio
for Visual C++
NI Switch Executive
Visual Basic
ANSI C/C++
NI-SWITCH
/CVI
NEW!
configurations by simply changing the terminal block. For example, you can
create an 8x32 two-wire matrix by using the NI SCXI-1335 terminal block with an
SCXI-1129 module. You can easily transform the same SCXI-1129 module into a
16x16 two-wire matrix by simply replacing the SCXI-1335 with an NI SCXI-1336
terminal block.
state of each matrix remains unchanged in the event of accidental power loss.
This feature prevents instruments and units under test from switching during
potentially damaging conditions. All relays open when power returns.
Automatic Scanning
NI 2529 modules can maximize throughput in automated test applications with
the use of scanning. Scanning improves throughput by downloading a list of
up to 32,000 connections to the switch and cycling through the list using an
event (trigger) without any interruption from the host processor. You can most
efficiently implement scanning by mating an NI 2529 or SCXI-1129 with an
instrument such as the NI PXI-4070 6½-digit FlexDMM, which issues a trigger
after each measurement.
Safety Disconnect
The SCXI-1129 incorporates a safety interlock that disconnects the SCXI
high-voltage analog bus from the matrix if the front terminal block is removed.
This arrangement prevents potentially hazardous voltages from appearing on
exposed front panel connector pins.
The NI 2529 modules use latching relays in the matrices to ensure that the

Related parts for NIPXI-2529

NIPXI-2529 Summary of contents

Page 1

High-Density Multiconfiguration Matrix Modules NI PXI-2529, NI PXIe-2529, NI SCXI-1129 8 matrix configurations Operating Systems ■ Switch capacity ■ ■ 150 VDC, 150 V CAT I ■ Recommended Software rms 1 A switching/2 A carry ■ ■ 32,000-step scan list ...

Page 2

High-Density Multiconfiguration Matrix Modules Terminal Block SCXI-1333 SCXI-1334 NI SCXI-1129 SCXI-1335 SCXI-1336 SCXI-1337 SCXI-1339 TB-2634 NI 2529 TB-2635 Table 1. NI 2529 and SCXI-1129 Configuration and Matrix Expansion Expansion with the SCXI-1129 Matrix modules can serve as building blocks for ...

Page 3

High-Density Multiconfiguration Matrix Modules Specifications Specifications subject to change without notice. Visit ni.com/manuals for the latest full specifications. Input Characteristics Maximum switching voltage................. 150 V (channel-to-channel and channel-to-ground) Maximum switching current ................. 1 A (per channel) Maximum carry current ......................... ...

Page 4

High-Density Multiconfiguration Matrix Modules Safety Compliance IEC 61010-1, EN 61010-1 ■ UL 61010-01, CSA 61010-1 ■ Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC ...

Page 5

NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and SERVICE NEEDS ongoing maintenance. We offer services and service ...