SC16C652BIBS PHILIPS [NXP Semiconductors], SC16C652BIBS Datasheet - Page 23

no-image

SC16C652BIBS

Manufacturer Part Number
SC16C652BIBS
Description
5V, 3.3 V and 2.5V dual UART, 5 Mbit/s (max.),with 32-byte FIFOs and infrared(IrDA) encoder/decoder
Manufacturer
PHILIPS [NXP Semiconductors]
Datasheet
Philips Semiconductors
9397 750 14452
Product data
7.6 Modem Control Register (MCR)
This register controls the interface with the modem or a peripheral device.
Table 20:
Bit
7
6
5
4
3
2
1
0
Symbol
MCR[7]
MCR[6]
MCR[5]
MCR[4]
MCR[3]
MCR[2]
MCR[1]
MCR[0]
Modem Control Register bits description
Rev. 03 — 10 December 2004
Description
Clock select
IR enable (see
Reserved; set to ‘0’.
Loop-back. Enable the local loop-back mode (diagnostics). In this
mode the transmitter output (TX) and the receiver input (RX), CTS,
DSR, CD, and RI are disconnected from the SC16C652B I/O pins.
Internally the modem data and control pins are connected into a
loop-back data configuration (see
and transmitter interrupts remain fully operational. The Modem
Control Interrupts are also operational, but the interrupts’ sources are
switched to the lower four bits of the Modem Control. Interrupts
continue to be controlled by the IER register.
OP2/INT enable
(OP1). OP1A/OP1B are not available as an external signal in the
SC16C652B. This bit is instead used in the Loop-back mode only. In
the loop-back mode, this bit is used to write the state of the modem RI
interface signal.
RTS
DTR
Logic 0 = Divide by 1 clock input.
Logic 1 = Divide by 4 clock input.
Logic 0 = Enable the standard modem receive and transmit
input/output interface (normal default condition).
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs.
While in this mode, the TX/RX output/inputs are routed to the
infrared encoder/decoder. The data input and output levels will
conform to the IrDA infrared interface requirement. As such, while
in this mode, the infrared TX output will be a logic 0 during idle data
conditions.
Logic 0 = Disable loop-back mode (normal default condition).
Logic 1 = Enable local loop-back mode (diagnostics).
Logic 0 = Forces INT (A-B) outputs to the 3-State mode and sets
OP2 to a logic 1 (normal default condition).
Logic 1 = Forces the INT (A-B outputs to the active mode and sets
OP2 to a logic 0.
Logic 0 = Force RTS output to a logic 1 (normal default condition).
Logic 1 = Force RTS output to a logic 0.
Logic 0 = Force DTR output to a logic 1 (normal default condition).
Logic 1 = Force DTR output to a logic 0.
Dual UART with 32-byte FIFOs and IrDA encoder/decoder
Figure
17).
Figure
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
5). In this mode, the receiver
SC16C652B
23 of 44

Related parts for SC16C652BIBS