X9319 Xicor, X9319 Datasheet - Page 7

no-image

X9319

Manufacturer Part Number
X9319
Description
Digitally Controlled Potentiometer (XDCP)
Manufacturer
Xicor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X9319UP
Manufacturer:
XICOR
Quantity:
20 000
Part Number:
X9319US8IZ
Manufacturer:
Intersil
Quantity:
100
Part Number:
X9319US8IZ
Manufacturer:
ADI
Quantity:
828
Part Number:
X9319W
Manufacturer:
ST
Quantity:
476
Part Number:
X9319WP
Manufacturer:
XICOR
Quantity:
20 000
Part Number:
X9319WS8IZ
Manufacturer:
Intersil
Quantity:
153
Part Number:
X9319WS8IZ
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
X9319WS8IZT1
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
X9319WSIZT1
Manufacturer:
INTERSIL
Quantity:
20 000
INSTRUCTIONS AND PROGRAMMING
The INC, U/D and CS inputs control the movement of
the wiper along the resistor array. With CS set LOW the
device is selected and enabled to respond to the U/D
and INC inputs. HIGH to LOW transitions on INC will
increment or decrement (depending on the state of the
U/D input) the seven bit counter. The output of this
counter is decoded to select one of one hundred wiper
positions along the resistive array.
The value of the counter is stored in nonvolatile mem-
ory whenever CS transitions HIGH while the INC input
is also HIGH.
The system may select the X9319, move the wiper and
deselect the device without having to store the latest
wiper position in nonvolatile memory. After the wiper
movement is performed as described above and once
the new position is reached, the system must keep INC
LOW while taking CS HIGH. The new wiper position
will be maintained until changed by the system or until
a powerup/down cycle recalled the previously stored
data. This procedure allows the system to always
power-up to a preset value stored in nonvolatile mem-
ory; then during system operation minor adjustments
could be made. The adjustments might be based on
user preference, system parameter changes due to
temperature drift, etc.
The state of U/D may be changed while CS remains
LOW. This allows the host system to enable the device
and then move the wiper up and down until the proper
trim is attained.
REV 1.7 7/10/03
www.xicor.com
MODE SELECTION
CS
H
L
L
INC
H
X
L
L
L
U/D
H
X
X
X
H
L
L
Wiper up
Wiper down
Store wiper position to
nonvolatile memory
Standby
No store, return to standby
Wiper Up (not recommended)
Wiper Down
(not recommended)
Mode
X9319
7 of 10