LTC693 LINER [Linear Technology], LTC693 Datasheet - Page 7

no-image

LTC693

Manufacturer Part Number
LTC693
Description
Microprocessor Supervisory Circuits
Manufacturer
LINER [Linear Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC6930CDCB-4.19
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC6930CDCB-4.19#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC6930CDCB-4.19#TRMPBF
Manufacturer:
LT凌特厂
Quantity:
20 000
Part Number:
LTC6930CDCB-5.00
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC6930CDCB-5.00#PBF
Manufacturer:
LT凌特厂
Quantity:
20 000
Part Number:
LTC6930CDCB-7.37
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC6930CDCB-7.37#TRMPBF
Manufacturer:
LT
Quantity:
124
Part Number:
LTC6930CDCB-8.00
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC6930CMS8-4.19#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC6930CMS8-5.00#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
PI FU CTIO S
OSC IN: Oscillator Input. OSC IN can be driven by an
external clock signal or an external capacitor can be
connected between OSC IN and GND when OSC SEL is
forced low. In this configuration the nominal reset active
time and watchdog time-out period are determined by
the number of clocks or set by the formula (see
BLOCK
U
U
I D AGRA
OSC SEL
OSC IN
V BATT
CE IN
WDI
V CC
PFI
U
W
TRANSITION
DETECTOR
1.3V
GND
OSC
+
+
+
C1
C2
C3
M2
RESET PULSE
GENERATOR
WATCHDOG
TIMER
Applications Information section). When OSC SEL is
high or floating, the internal oscillator is enabled and the
reset active time is fixed at 200ms typical. OSC IN selects
between the 1.6 seconds and 100ms typical watchdog
time-out periods. In both cases the time-out period
immediately after a reset is 1.6 seconds typical.
CHARGE
PUMP
M1
LTC692/LTC693
LTC692/3 • BD
BATT ON
CE OUT
LOW LINE
PFO
RESET
RESET
WDO
V OUT
7