Datasheet
6.1
6.2
6.3
6.4
6.5 Soldering Test
6.6 Solderability
6.7 Drop test
6.8 Vibration
6.9 Board Bending
6. Reliability Specifications
SHENZHEN LUGUANG ELECTRONIC TECHNOLOGY CO.,LTD.
Thermal Shock
Humidity Test
High Temp
LowTemp
Storage
Storage
Item
http://www.luguang.cn
Stored in _40±3℃for 96 hours, and left at room
temp.for 1 hour before measurement.
Stored in 85±2℃ for 96 hours, and left at room
temp.for 1 hour before measurement.
Stored at40±2,in90~95﹪R.H.for96 hours ,and left
at room temp.for 1 hour before measurement.
After temp.cycling of _40℃(30minutes) to +85℃
(30minutes) was performed 5 times, filter shall be
measured after being placed in natural condition for
1 hour.
Passed thtough the reflow oven under the following
condition for 2 times, and left at room temp. for 24
hours before measurement.
Dipped in 35±5℃ solder bath for 3±0.5
Seconds with rosin flrx
Free drop to the wood plate from the height of 70
cm for 3 times.
Apply the vibration of weep frequency 10 to
55Hz/minutes,amplitude 1.5mm, duration 2 hours
in each direction of 3 planes.
Mount on a glass-epoxy
board(width=50mm,thickness=1.6mm)then bend it
to 1mm displacement(velocity 1mm/sec) and keep
it for 5 seconds
Temp. at the surface
Of the substeate
Preheat 150±5℃
Peak 235±5℃
Test Condition
60~100sec
Less than 10 sec
Time
Email: lge@luguang.cn
Meet Table 1
The terminals
Shall be at least95
﹪ covered by
solder
Meet Table 1
Meet Table 1
Mechanical
damage such as
break shall not
occur
Meet Table 1
Meet Table 1
Meet Table 1
Meet Table 1
Spec
3