MAX3097 MAXIM [Maxim Integrated Products], MAX3097 Datasheet - Page 6

no-image

MAX3097

Manufacturer Part Number
MAX3097
Description
Manufacturer
MAXIM [Maxim Integrated Products]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX3097ECEE+T
Manufacturer:
MAXIM
Quantity:
60
Part Number:
MAX3097ECSE+
Manufacturer:
Maxim
Quantity:
150
Part Number:
MAX3097ECSE+T
Manufacturer:
Maxim
Quantity:
5 000
Part Number:
MAX3097ECSE+T
Manufacturer:
MAXIM
Quantity:
3
Part Number:
MAX3097EEEE+T
Manufacturer:
MAXIM
Quantity:
5 000
Part Number:
MAX3097EEEE+T
0
Part Number:
MAX3097EESE+
Manufacturer:
Maxim
Quantity:
36
Part Number:
MAX3097ESE
Manufacturer:
MAXIM/美信
Quantity:
20 000
±15kV ESD-Protected, 32Mbps, 3V/5V,
Triple RS-422/RS-485 Receivers with Fault Detection
6
_______________________________________________________________________________________
PIN
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
ALARMD
ALARMZ
ALARMB
ALARMA
DELAY
NAME
OUTZ
OUTB
OUTA
GND
V
A
A
B
B
Z
Z
CC
Noninverting Receiver A Input
Inverting Receiver A Input
Noninverting Receiver B Input
Inverting Receiver B Input
Noninverting Receiver Z Input
Inverting Receiver Z Input
Ground
Programmable Delay Terminal. Connect a capacitor from DELAY to GND to set the
ALARMD output delay time. To obtain a minimum delay, leave DELAY unconnected. See
Capacitance vs. ALARMD Output Delay in the Typical Operating Characteristics.
Delayed Fault Output. This output is the logic OR of ALARMA, ALARMB, and ALARMZ.
Place a capacitor from the DELAY pin to GND to set the delay (see Setting Delay Time). A
high logic level indicates a fault condition on at least one receiver input pair. A low level on
this pin indicates no fault condition is present.
Z Receiver Output. If V
be low. If Z or Z exceeds the receiver’s input common-mode voltage range, the ALARMZ
output will be high and OUTZ will be indeterminate.
Z Fault Output. When ALARMZ is high, OUTZ is indeterminate. Tables 1 and 2 show all the
possible states for which an alarm is set.
B Receiver Output. If V
be low. If B or B exceeds the input receiver’s common-mode voltage range, the ALARMB
output will be high and OUTB will be indeterminate.
B Fault Output. When ALARMB is high, OUTB is indeterminate. Tables 1 and 2 show all the
possible states for which an alarm is set.
A Receiver Output. If V
be low. If A or A exceeds the receiver’s input common-mode voltage range, the ALARMA
output will be high and OUTA will be indeterminate.
A Fault Output. When ALARMA is high, OUTA is indeterminate. Tables 1 and 2 show all the
possible states for which an alarm is set.
Power Supply
Z
B
A
- V
- V
- V
Z
B
A
≥ +200mV, OUTZ will be high. If V
≥ +200mV, OUTB will be high. If V
≥ +200mV, OUTA will be high. If V
FUNCTION
Z
A
B
- V
Pin Description
- V
- V
Z
A
B
≤ -200mV, OUTZ will
≤ -200mV, OUTA will
≤ -200mV, OUTB will

Related parts for MAX3097