M41T65 STMICROELECTRONICS [STMicroelectronics], M41T65 Datasheet - Page 13

no-image

M41T65

Manufacturer Part Number
M41T65
Description
Serial real-time clocks with alarm
Manufacturer
STMICROELECTRONICS [STMicroelectronics]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M41T65
Manufacturer:
ST
0
Part Number:
M41T6506F
Manufacturer:
ST
0
Part Number:
M41T65Q
Manufacturer:
ST
0
Part Number:
M41T65Q6F
Manufacturer:
VK
Quantity:
3 200
Part Number:
M41T65Q6F
Manufacturer:
ST
0
Part Number:
M41T65Q6F
Manufacturer:
ST
Quantity:
20 000
M41T62/63/64/65
2.1.4
2.1.5
Data valid
The state of the data line represents valid data when after a start condition, the data line is
stable for the duration of the high period of the clock signal. The data on the line may be
changed during the Low period of the clock signal. There is one clock pulse per bit of data.
Each data transfer is initiated with a start condition and terminated with a stop condition.
The number of data bytes transferred between the start and stop conditions is not limited.
The information is transmitted byte-wide and each receiver acknowledges with a ninth bit.
By definition a device that gives out a message is called “transmitter,” the receiving device
that gets the message is called “receiver.” The device that controls the message is called
“master.” The devices that are controlled by the master are called “slaves.”
Acknowledge
Each byte of eight bits is followed by one acknowledge bit. This acknowledge bit is a low
level put on the bus by the receiver whereas the master generates an extra acknowledge
related clock pulse. A slave receiver which is addressed is obliged to generate an
acknowledge after the reception of each byte that has been clocked out of the slave
transmitter.
The device that acknowledges has to pull down the SDA line during the acknowledge clock
pulse in such a way that the SDA line is a stable Low during the high period of the
acknowledge related clock pulse. Of course, setup and hold times must be taken into
account. A master receiver must signal an end of data to the slave transmitter by not
generating an acknowledge on the last byte that has been clocked out of the slave. In this
case the transmitter must leave the data line high to enable the master to generate the
STOP condition.
Figure 14. Serial bus data transfer sequence
CLOCK
DATA
CONDITION
START
Doc ID 10397 Rev 14
DATA VALID
DATA LINE
STABLE
DATA ALLOWED
CHANGE OF
CONDITION
STOP
Operation
AI00587
13/41