M41T62_06 STMICROELECTRONICS [STMicroelectronics], M41T62_06 Datasheet - Page 31

no-image

M41T62_06

Manufacturer Part Number
M41T62_06
Description
Serial Access Real-Time Clock with Alarms
Manufacturer
STMICROELECTRONICS [STMicroelectronics]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M41T62_06M41T62Q06F
Manufacturer:
ST
0
M41T62/63/64/65
5
DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the Measurement Conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 12.
1. Output Hi-Z is defined as the point where data is no longer driven.
Figure 23. AC measurement I/O waveform
Figure 24. Crystal isolation example
1. Substrate pad should be tied to V
Supply voltage (V
Ambient operating temperature (T
Load capacitance (C
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
Operating and AC measurement conditions
CC
)
L
)
0.8V CC
0.2V CC
Local Grounding Plane
(Layer 2)
Parameter
Crystal
SS
A
.
)
XI
XO
GND
AI09127
(1)
0.7V CC
0.3V CC
AI02568
DC and AC parameters
0.2V
0.3V
1.3V to 4.4V
–40 to 85°C
CC
CC
M41T6x
50pF
5ns
to 0.8 V
to 0.7 V
CC
CC
31/40