Z86130 ZILOG [Zilog, Inc.], Z86130 Datasheet - Page 32

no-image

Z86130

Manufacturer Part Number
Z86130
Description
NTSC LINE 21 DECIDER
Manufacturer
ZILOG [Zilog, Inc.]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8613012PSC
Manufacturer:
MT
Quantity:
11
Part Number:
Z8613012PSC
Manufacturer:
ZILOG
Quantity:
20 000
Part Number:
Z8613012SSC
Manufacturer:
ZILOG
Quantity:
8 000
Part Number:
Z8613012SSC
Manufacturer:
ZILOG
Quantity:
20 000
Part Number:
Z8613012SSC00TR
Manufacturer:
AVAGO
Quantity:
7
Part Number:
Z8613012SSC00TR
Manufacturer:
ZILOG
Quantity:
20 000
Z86129/130/131
NTSC Line 21 Decoder
INTERNAL REGISTERS (Continued)
XDS data and header information (including START,
CONTINUE, and END commands) are passed through the
filter for the XDS class and type specified in the XDS Filter
Register. All other Line 21 data is filtered out and will not
be output, or used to generate a data available flag (DAV)
in the Serial Status Register.
To
Z86129/130/131, the master device must first write the
XDS Filter Register (05h) with its desired XDS Class and
Type information. For example, in order to extract ONLY
the Line 21 Program Rating information, the master must
write the value 61h to the XDS Filter Register. The master
should then poll the state of the DAV bit in the SSR until
DAV = 1.
As soon as DAV=1, the master may initiate a 3-byte read
in the normal manner (XDS data bytes always arrive in
pairs, so it is safe to assume that RD2=1 when DAV=1 in
the SSB). A 3-byte read always yields two data bytes,
which in this case will be the first two bytes of the Current
Class,
encountered on Line21 field 2. The master device must
then interpret those two bytes according to EIA-608
specifications for Current Class, Program Rating Type
data. Refer to EIA-608 for data formats.
32
properly
Program
read
Rating
filtered
Type
XDS
XDS
data
data
from
P R E L I M I N A R Y
stream
the
The XDS filters on the Z86129/130/131 greatly reduce the
amount of field 2 data passed on to the master device for
further processing and interpretation. However, the master
device must still interpret the filtered data stream in
accordance with EIA-608. The filtered data stream from
the Z86129/130/131 will be in full compliance with EIA-
608. In other words, the filtered data stream will contain all
the XDS command and data packets, in standard EIA-608
format, but only for the selected XDS Class and Type(s).
Note: The Z86129/130 XDS filter for Program Rating
information behaves differently than all other Z86129/130
predefined XDS filters. This change has been made to
minimize the amount of data passed through the Program
Rating XDS filter, thereby minimizing the interpretation
and communications load on the master device. When the
XDS Filter Register is set to 61h (Class=01h (Current),
Type=05h (Program Rating) the only data from Line 21
field 2 that will pass through the filter is:
1. Program Rating Packet: [xxh,00h]. The Current Class
2. The END Packet [0Fh,CHKSUM]. A two-byte packet
Program Rating data byte pair as defined in EIA-608.
The program’s rating is encoded per EIA-608 in the
byte xxh.
that includes a CHKSUM computed per EIA-608. The
checksum calculation includes the START packet
[01h,05h] even though this value was not passed
through the filter.
DS96TEL0200

Related parts for Z86130