When a short-circuit of FLT with VDD occurs the output goes to the high fault band. For all other internal faults
the output goes to the low fault band.
External faults
Short-circuit
In all of these above mentioned fault cases, the IC will generate an output within either of the diagnostic bands.
Open circuit
In case of open circuit the output will go to the high fault band.
The MLX90320 must survive to the following reversed contacts but the output does not go to the fault bands.
3901090320
Rev 004
Output with VDD
Output with GND
Output with Vbat
VDD open
GND open
Reverse polarity
Reverse battery polarity
Output reversed with GND
Output reversed with VDD
Page 17 of 32
Automotive small sensor interface
MLX90320
Data Sheet
Mar/05