MLX90808LUF-2 MELEXIS [Melexis Microelectronic Systems], MLX90808LUF-2 Datasheet

no-image

MLX90808LUF-2

Manufacturer Part Number
MLX90808LUF-2
Description
Absolute Integrated Pressure Sensor
Manufacturer
MELEXIS [Melexis Microelectronic Systems]
Datasheet
Features and Benefits
Application Examples
Ordering Information
Part No.
MLX90808
1 Functional Diagram
3901090808
Rev 001
Absolute Integrated Pressure sensor
Less than 1% error range overall
Programmable through the connector (3 pins)
Trimmable offset and sensitivity
Ratiometric output
Rail-to-Rail output
Output proportional to the applied pressure
Diagnostics of broken supply wires and broken sensor
Output protected against short-circuits at both battery terminals
On-chip Signal Conditioning (single die solution)
Different pressure ranges available
Automotive applications (MAP, T-MAP, HVAC, …)
Industrial applications
Barometric Air Pressure
Temperature Suffix
L (-40° C to 150°C)
Package Code
UF (die on foil)
Page 1 of 8
Absolute Integrated Pressure Sensor
The MLX90808 is an integrated absolute
pressure sensor realised in CMOS
technology. It consists of an analog signal
chain that interacts with the digital core and
on-chip temperature sensor in order to
provide uniform overall sensing
characteristics after calibration and to cancel
the temperature related parameter drifts.
The output is proportional to the applied
pressure with an adjustable slope and offset.
The chip is ratiometric and goes rail-to-rail
with a 1mA source and sink capability.
2
Option
- 2
General Description
Description
3 to 7 Bar Pressure Span
MLX90808
Data Sheet
Feb 08

Related parts for MLX90808LUF-2

MLX90808LUF-2 Summary of contents

Page 1

Features and Benefits Absolute Integrated Pressure sensor Less than 1% error range overall Programmable through the connector (3 pins) Trimmable offset and sensitivity Ratiometric output Rail-to-Rail output Output proportional to the applied pressure Diagnostics of broken supply wires and broken ...

Page 2

Table of Contents 1 Functional Diagram........................................................................................................... 1 2 General Description .......................................................................................................... 1 3 Absolute Maximum Ratings .............................................................................................. 3 4 General Electrical Specifications....................................................................................... 3 5 Diagnostic features ........................................................................................................... 4 6 Detailed General Description ............................................................................................ 4 7 Unique Features ............................................................................................................... 5 8 ...

Page 3

Absolute Maximum Ratings Parameter Table 1: Absolute maximum ratings Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum- rated conditions for extended periods may affect device reliability. 4 General Electrical Specifications DC Operating Parameters T = ...

Page 4

Diagnostic features DC Operating Parameters T = -40 A Parameter Symbol Table 3: Diagnostic features 6 Detailed General Description This chip integrates a pressure sensor and the associated signal conditioning on the same die. The supply voltage V directly ...

Page 5

Unique Features Diagnostic Limits Diagnostic of broken sensor: The output will be forced to ground (or a very low level) when the sensor membrane breaks. Diagnostic of broken wires: The output will be forced to ground (or a very ...

Page 6

Programming and Calibration 9.1 Programming of the Temporary Memory of 90808 The temporary memory consists of a shift register of flip flops used to search for the correct calibration settings. Mode 1 (TC[5:0]=01h) is used for this ...

Page 7

Zapping of the 90808 The permanent memory of the 90808 is built with zap cells. The data output of an unprogrammed zap cell is 0. The data output is 1 when the cell is zapped not possible ...

Page 8

Disclaimer Devices sold by Melexis are covered by the warranty and patent indemnification provisions appearing in its Term of Sale. Melexis makes no warranty, express, statutory, implied description regarding the information set forth herein or regarding the ...