ADL5500-EVALZ AD [Analog Devices], ADL5500-EVALZ Datasheet - Page 7

no-image

ADL5500-EVALZ

Manufacturer Part Number
ADL5500-EVALZ
Description
100 MHz to 6 GHz TruPwr Detector
Manufacturer
AD [Analog Devices]
Datasheet
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter
Supply Voltage V
VRMS
RFIN
Equivalent Power, re 50 Ω
Internal Power Dissipation
θ
Maximum Junction Temperature
Operating Temperature Range
Storage Temperature Range
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
JA
(WLCSP)
S
Rating
5.5 V
0 V, V
1.25 V rms
15 dBm
150 mW
260°C/W
125°C
−40°C to +85°C
−65°C to +150°C
S
Rev. A | Page 7 of 24
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ADL5500