TSL120-124P TRACOPOWER [TRACO Electronic AG], TSL120-124P Datasheet - Page 2

no-image

TSL120-124P

Manufacturer Part Number
TSL120-124P
Description
Industrial Power Supplies
Manufacturer
TRACOPOWER [TRACO Electronic AG]
Datasheet
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Ripple and Noise (20MHz Bandwidth)
Parallel operation
User selectable standard operation mode or parallel operation mode
(see TSL instruction manual)
Overvoltage protection, triggerpoint at
Input Specifications
Input voltage range – TSL 030, TSL 060
Input frequency
Input current at full load (typ.)
– TSL 030
– TSL 120
– TSL 240
Inrush current (< 2 ms)
– TSL 030
– TSL 240
– TSL 480
Output Specifications
Output voltage adj. range
Regulation – Input variation
Electronic short circuit protection
Hold-up time
– TSL 030 ... TSL 120
– TSL 060
– TSL 480
– TSL 060
– TSL 120
– TSL 240
– TSL 480
– Load variation (10 – 90 %)
– TSL 120 … TSL 480
– 12 VDC models
– 24 VDC models
– 48 VDC models
93 – 264 VAC
93 – 132 VAC / 187 – 264 VAC
47 – 63 Hz
115 VAC
0.5 A
1.1 A
1.9 A
3.5 A
7.2 A
115 VAC
< 17.5 A
< 24
< 24
< 35
< 33
12 – 14 VDC
24 – 28 VDC
48 – 52 VDC
48 – 55 VDC on request ( Option-BC)
± 0.2 % max.
± 0.3 % max.
(± 1.5 % in parallel operation)
< 50 mV pk-pk
(constant current, automatic restart)
min. 25 ms
min. 20 ms
min. 15 ms
current limitation at 110 % typ.
5 units max.
140 % typ. Vout nom.
115 VAC
Industrial Power Supplies
TSL Series
A
A
A
A
230 VAC
0.3 A
0.65 A
1.2 A
1.7 A
3.5 A
230 VAC
< 35 A
< 48 A
< 48 A
< 69 A
< 65 A
230 VAC
min. 30 ms
min. 40 ms
min. 25 ms
30-480 Watt
Page 2