GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Turn-On time for random turn-on versions is 0.1 msec (DC Control Models).
INPUT SPECIFICATIONS (1)
Description
Nominal Voltage
Control Voltage Range
Minimum Turn-On Voltage
Drop Out Voltage
Typical Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec] (3)
Maximum Turn-Off Time [msec]
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
WIRING DIAGRAM
CX240Dx
3-15 VDC
300 Ohm
1/2 Cycle
1/2 Cycle
15 mAdc
3.0 VDC
1.0 VDC
5 VDC
CX380/480Dx
4-15 VDC
240 Ohm
1/2 Cycle
1/2 Cycle
15 mAdc
4.0 VDC
1.0 VDC
5 VDC
CXExxxDx
15-32 VDC
1500 Ohm
15.0 VDC
1/2 Cycle
1/2 Cycle
15 mAdc
1.0 VDC
24 VDC
Therminally Conductive Epoxy
Parameters
-30 to 125 °C
0.4 oz. (11g)
-30 to 80 °C
4000 Vrms
10
10 pF
9
Ohm
90-140 VAC
CX240A5
14.1K Ohm
90.0 Vrms
10.0 Vrms
10 mArms
120 VAC
10
40
CXE240A5
18-36 VAC
18.0 Vrms
10 mArms
2.1K Ohm
2.0 Vrms
24 VAC
10
40